Rear Door RH Entry Lock Function does not Operate: Procedure
- CHECK POWER DOOR LOCK OPERATION
- When the master switch assembly's door control switch is operated, check that the locked doors unlock.RESULT
Result Proceed to Door locks operate normally OK Door locks do not operate normally NG
NG → See step 10
OK: Go to next step
- When the master switch assembly's door control switch is operated, check that the locked doors unlock.
- READ VALUE USING TECHSTREAM (DOOR LOCK POSITION SWITCH)
- Using the Techstream, read the Data List.REAR RIGHT DOOR (REAR DOOR ECU RH)
Tester Display Measurement Item/Display Normal Condition Lock Position SW Rear RH side door lock position switch signal / ON or OFF ON: Rear RH side door is unlocked
OFF: Rear RH side door is lockedOK
On the screen, item changes between ON and OFF according to above chart.
NG → See step 12
OK: Go to next step
- Using the Techstream, read the Data List.
- READ VALUE USING TECHSTREAM (OUTSIDE HANDLE)
- Using the Techstream, read the Data List.REAR RIGHT DOOR (REAR DOOR ECU RH)
Tester Display Measurement Item/Display Normal Condition Outside Handle Trigger SW Rear RH side door outside handle lock switch / ON or OFF ON: Rear RH side door outside handle lock switch is pushed
OFF: Rear RH side door outside handle lock switch is not pushedOK
On the screen, item changes between ON and OFF according to above chart.
NG → See step 5
OK: Go to next step
- Using the Techstream, read the Data List.
- CHECK REAR DOOR ECU RH (OPERATION)
- Replace the rear door ECU RH with a new one or normally functioning one. Refer toCOMPONENTS .
- Check that the entry function operates normally.
OK
Operates normally
NG → REPLACE CERTIFICATION ECU
OK → END (REAR DOOR ECU RH IS DEFECTIVE)
- INSPECT REAR DOOR OUTSIDE HANDLE RH
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Switch Condition Specified Condition c1-3 (TRG+) - c1-1 (TRG-) ON Below 1 Ω c1-3 (TRG+) - c1-1 (TRG-) OFF 10 kΩ or higher
NG → See step 11
OK: Go to next step
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (REAR DOOR OUTSIDE HANDLE RH - REAR DOOR ECU RH)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Disconnect the c1 handle connector.
- Disconnect the O3 ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition c1-3 (TRG+) - O3-20 (TRG+) Always Below 1 Ω c1-3 (TRG+) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (REAR DOOR OUTSIDE HANDLE RH - DOOR ELECTRICAL KEY OSCILLATOR)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Disconnect the c1 handle connector.
- Disconnect the c2 oscillator connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition c1-1 (TRG-) - c2-9 (TRG-) Always Below 1 Ω c1-1 (TRG-) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK DOOR ELECTRICAL KEY OSCILLATOR (OPERATION)
- Replace the door electrical key oscillator with a new one or normally functioning one. Refer toCOMPONENTS .
- Check that the entry function operates normally.
OK
Operates normally
NG → See step 9
OK → END (DOOR ELECTRICAL KEY OSCILLATOR IS DEFECTIVE)
- CHECK REAR DOOR ECU RH (OPERATION)
- Replace the rear door ECU RH with a new one or normally functioning one. Refer toCOMPONENTS .
- Check that the entry function operates normally.
OK
Operates normally
NG → REPLACE CERTIFICATION ECU
OK → END (REAR DOOR ECU RH IS DEFECTIVE)
- GO TO POWER DOOR LOCK CONTROL SYSTEM. Refer to PRECAUTION
- REPLACE REAR DOOR OUTSIDE HANDLE RH. Refer to COMPONENTS
- GO TO POWER DOOR LOCK CONTROL SYSTEM (Proceed to Only Rear Door RH LOCK/UNLOCK Functions do not Operate). Refer to PROBLEM SYMPTOMS TABLE