Typical Enabling Conditions
ECT SENSOR COLD START MONITOR
| Monitor runs whenever following DTCs are not present | None |
| Battery voltage | 10.5 V or more |
| Time after engine start | 1 second or more |
| ECT at engine start | Less than 60°C (140°F) |
| ECT sensor circuit (P0115, P0117, P0118, P0125) | OK |
| IAT sensor circuit (P0112, P0113) | OK |
| Thermostat fail (P0128) | OK |
| Soak time | 0 second or more |
| Accumulated MAF | 1564 g or more |
| Engine | Running |
| Fuel cut | OFF |
| Difference between ECT at engine start and IAT | Less than 40°C (72°F) |
ECT SENSOR SOAK MONITOR
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 10.5 V or more |
| Engine | Running |
| ECT sensor circuit (P0115, P0117, P0118) | OK |
| IAT sensor circuit (P0112, P0113) | OK |
| Thermostat fail (P0128) | OK |
| Soak timer circuit (P2610) | OK |
| Soak time | 5 hours or more |
| Either of the following conditions is met: | (a) or (b) |
| (a) ECT at engine start | 60°C (140°F) or more |
| (b) Accumulated MAF | 3232 g or more |