DTC C1AC1: Master Module Horizontal Axis Misalignment [09/2014 - 10/2015]: Procedure
- CHECK INSTALLATION CONDITION
- Check the installation condition of the blind spot monitor sensor RH (See page. Refer to INSTALLATION [09/2014 - ]
).
HINT:
Take the appropriate action in accordance with the result.
Result: NEXT
NEXT
See step 2
- Check the installation condition of the blind spot monitor sensor RH (See page. Refer to INSTALLATION [09/2014 - ]
).
- PERFORM BEAM AXIS CONFIRMATION
- Install the rear bumper (See page. Refer to REMOVAL [09/2014 - 09/2016] ).
- Perform Blind Spot Monitor Beam Axis Confirmation using the Techstream (See page. Refer to OPERATION CHECK [09/2014 - 10/2015] ).
Result: OK
OK
END
Result: NG
NG
REPLACE BLIND SPOT MONITOR SENSOR RH
(See page. Refer to REMOVAL [09/2014 - ] )