DTC C1AC1: Master Module Horizontal Axis Misalignment [09/2016 - ]: Procedure
- CHECK INSTALLATION CONDITION
- Check the installation condition of the blind spot monitor sensor RH (See page. Refer to INSTALLATION [09/2014 - ]
).
HINT:
Take the appropriate action in accordance with the result.
Result: NEXT
NEXT
See step 2
- Check the installation condition of the blind spot monitor sensor RH (See page. Refer to INSTALLATION [09/2014 - ]
).
- PERFORM BEAM AXIS CONFIRMATION
- Install the rear bumper.
Refer to REMOVAL [09/2016 - ]
- Perform Blind Spot Monitor Beam Axis Confirmation using the Techstream (See page. Refer to OPERATION CHECK [09/2016 - ] ).
Result: OK
OK
END
Result: NG
NG
REPLACE BLIND SPOT MONITOR SENSOR RH
(See page. Refer to REMOVAL [09/2014 - ] )
- Install the rear bumper.