Home >> Lexus >> 2016 >> GX 460 Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (Diagnostic Codes) (3 Of 7) >> SFI System >> DTC P0400: Exhaust Gas Recirculation Flow; DTC P0401: Exhaust Gas Recirculation Flow Insufficient Detected; DTC P0402: Exhaust Gas Recirculation Flow Excessive Detected [08/2022 - ] >> Monitor Strategy
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Monitor Strategy

P0400

Related DTC P0400: EGR valve flow functional
Required Sensors/Components (Main) EGR valve assembly
Manifold absolute pressure sensor
Required Sensors/Components (Related) Crankshaft position sensor
Camshaft position sensor
Vehicle speed sensor
Engine coolant temperature sensor
Mass air flow meter sub-assembly
Frequency of Operation Once per driving cycle
Duration Within 3 seconds
MIL operation 2 driving cycles
Sequence of operation None
P0401, P0402

Related DTC P0401: EGR valve low flow rate
P0402: EGR valve high flow rate
Required Sensors/Components (Main) EGR valve assembly
Manifold absolute pressure sensor
Required Sensors/Components (Related) Crankshaft position sensor
Camshaft position sensor
Vehicle speed sensor
Engine coolant temperature sensor
Mass air flow meter sub-assembly
Frequency of Operation Once per driving cycle
Duration Within 3 seconds
MIL operation 1 driving cycle
Sequence of operation Stored when DTC P0400 is stored in the second trip