DTC P00AC: Intake Air Temperature Sensor 1 Circuit Low Bank 2; DTC P00AD: Intake Air Temperature Sensor 1 Circuit High Bank 2; DTC P0112: Intake Air Temperature Circuit Low Input; DTC P0113: Intake Air Temperature Circuit High Input [09/2015 - ]: Procedure
- READ VALUE USING TECHSTREAM (INTAKE AIR TEMPERATURE)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air Temp B1S1 or Intake Air Temp B2S1.
- Read the value displayed on the Techstream.
Standard
Same as actual Intake Air Temperature (IAT).
Result
Temperature Displayed Proceed to -40°C (-40°F) A 140°C (284°F) or higher B Same as actual IAT C HINT:
- If there is an open circuit, the Techstream indicates -40°C (-40°F).
- If there is a short circuit, the Techstream indicates 140°C (284°F) or higher.
Result: B
B
See step 4
Result: C
C
CHECK FOR INTERMITTENT PROBLEMS
(Refer to CHECK FOR INTERMITTENT PROBLEMS [09/2015 - ] )
Result: A
A
See step 2
- READ VALUE USING TECHSTREAM (CHECK FOR OPEN IN WIRE HARNESS)
- Disconnect the E13 or E22 MAF meter connector.
- Connect terminals THA and E2 or THAR and E2R of the MAF meter wire harness side connector.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air Temp B1S1 or Intake Air Temp B2S1.
- Read the value displayed on the Techstream.
Standard
140°C (284°F) or higher
HINT:
Perform "Inspection After Repair" after replacing the mass air flow meter (Refer to INITIALIZATION [09/2015 - ] ).
Result: OK
OK
CONFIRM GOOD CONNECTION TO SENSOR. IF OK, REPLACE MASS AIR FLOW METER
(Refer to REMOVAL [09/2015 - ] )
Result: NG
NG
See step 3
- READ VALUE USING TECHSTREAM (CHECK FOR OPEN IN ECM)
- Disconnect the E13 or E22 MAF meter connector.
- Connect terminals THA and E2 or THA2 and E2 of the E1 ECM connector.
HINT:
Before checking, do visual and contact pressure checks on the ECM connector.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air Temp B1S1 or Intake Air Temp B2S1.
- Read the value displayed on the Techstream.
Standard
140°C (284°F) or higher
Result: NG
NG
CONFIRM GOOD CONNECTION TO ECM. IF OK, REPLACE ECM
(Refer to REMOVAL [09/2015 - ] )
Result: OK
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR
- READ VALUE USING TECHSTREAM (CHECK FOR SHORT IN WIRE HARNESS)
- Disconnect the E13 or E22 MAF meter connector.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air Temp B1S1 or Intake Air Temp B2S1.
- Read the value displayed on the Techstream.
Standard
-40°C (-40°F)
HINT:
Perform "Inspection After Repair" after replacing the mass air flow meter (Refer to INITIALIZATION [09/2015 - ] ).
Result: OK
OK
REPLACE MASS AIR FLOW METER
(Refer to REMOVAL [09/2015 - ] )
Result: NG
NG
See step 5
- READ VALUE USING TECHSTREAM (CHECK FOR SHORT IN ECM)
- Disconnect the E13 or E22 MAF meter connector.
- Disconnect the E1 ECM connector.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air Temp B1S1 or Intake Air Temp B2S1.
- Read the value displayed on the Techstream.
Standard
-40°C (-40°F)
Result: NG
NG
REPLACE ECM
(Refer to REMOVAL [09/2015 - ] )
Result: OK
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR