Home >> Lexus >> 2016 >> LX 570 >> Repair and Diagnosis (Single Page) >> Body & Frame >> Windows >> Power Window Control System - Diagnostic Codes & Symptom Tests >> Power Window Control System >> Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) [09/2015 - ] >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) [09/2015 - ]: Procedure

  1. PERFORM INITIALIZATION 
    1. Initialize the power window regulator motor. Refer to INITIALIZATION [09/2015 - ] .
    2. Check if the power window auto up/down function operates. Refer to OPERATION CHECK [09/2015 - ] .

      OK

      Auto up/down function operates.

    Result: 

    OK 

    END (PROBLEM DUE TO INITIALIZATION FAILURE) 

    Result: 

    NG 

    See step  2

  2. CHECK MOVEMENT OF DOOR GLASS (LOCATION WHERE JAM PROTECTION FUNCTION OPERATES) 
    1. Remove the installation bolt of the door glass and hold the glass by hand. When raising the glass by hand, check that the glass moves smoothly.
      NOTE:
      • Make sure that the door glass fits to the glass run properly.
      • Make sure that the glass run is not deformed, and that there is no foreign matter on the glass run.

      OK

      Door glass moves smoothly.

    Result: 

    OK 

    REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (APPLICABLE LOCATION) 

    Result: 

    NG 

    INSTALL DOOR GLASS AND/OR GLASS RUN PROPERLY (APPLICABLE LOCATION)