Millimeter Wave Radar Sensor Power Source Circuit [04/2013 - 10/2016]: Procedure
- CHECK TERMINAL VOLTAGE (POWER SOURCE OF MILLIMETER WAVE RADAR SENSOR ASSEMBLY)
- Disconnect the B8 millimeter wave radar sensor assembly connector.
*a Front view of wire harness connector
(to Millimeter Wave Radar Sensor Assembly) - Measure the voltage and resistance according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition B8-5 (IGB) - Body ground Engine switch on (IG) 11 to 14 V B8-5 (IGB) - Body ground Engine switch off Below 1 V Standard Resistance
Tester Connection Condition Specified Condition B8-1 (SGND) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [04/2013 - 08/2015] , or refer to PROBLEM SYMPTOMS TABLE [08/2015 - 10/2016]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (MILLIMETER WAVE RADAR SENSOR ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the B8 millimeter wave radar sensor assembly connector.