LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2017 >> RX 450h Base >> Repair and Diagnosis (Single Page) >> Hybrid/Electric Powertrain >> Battery Management Systems >> Hybrid Battery System (Diagnostic Codes) (2 Of 2) >> Hybrid Battery System >> DTC P3011-123: Battery Block 1 Becomes Weak; DTC P3012-123: Battery Block 2 Becomes Weak; DTC P3013-123: Battery Block 3 Becomes Weak; DTC P3014-123: Battery Block 4 Becomes Weak; DTC P3015-123: Battery Block 5 Becomes Weak; DTC P3016-123: Battery Block 6 Becomes Weak; DTC P3017-123: Battery Block 7 Becomes Weak; DTC P3018-123: Battery Block 8 Becomes Weak; DTC P3019-123: Battery Block 9 Becomes Weak; DTC P3020-123: Battery Block 10 Becomes Weak; DTC P3021-123: Battery Block 11 Becomes Weak; DTC P3022-123: Battery Block 12 Becomes Weak; DTC P3023-123: Battery Block 13 Becomes Weak; DTC P3024-123: Battery Block 14 Becomes Weak; DTC P3025-123: Battery Block 15 Becomes Weak [10/2015 - ] >> Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P3011-123: Battery Block 1 Becomes Weak; DTC P3012-123: Battery Block 2 Becomes Weak; DTC P3013-123: Battery Block 3 Becomes Weak; DTC P3014-123: Battery Block 4 Becomes Weak; DTC P3015-123: Battery Block 5 Becomes Weak; DTC P3016-123: Battery Block 6 Becomes Weak; DTC P3017-123: Battery Block 7 Becomes Weak; DTC P3018-123: Battery Block 8 Becomes Weak; DTC P3019-123: Battery Block 9 Becomes Weak; DTC P3020-123: Battery Block 10 Becomes Weak; DTC P3021-123: Battery Block 11 Becomes Weak; DTC P3022-123: Battery Block 12 Becomes Weak; DTC P3023-123: Battery Block 13 Becomes Weak; DTC P3024-123: Battery Block 14 Becomes Weak; DTC P3025-123: Battery Block 15 Becomes Weak [10/2015 - ]: Description

Refer to the description for DTC P0A80-123.

Refer to DESCRIPTION

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P3011-123 Battery Block 1 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3012-123 Battery Block 2 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3013-123 Battery Block 3 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3014-123 Battery Block 4 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3015-123 Battery Block 5 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
  • Service Plug Grip
  • Electric vehicle battery plug assembly
  • No. 2 HV battery pack cable
Comes on Master Warning Light:
Comes on
P3016-123 Battery Block 6 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3017-123 Battery Block 7 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3018-123 Battery Block 8 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3019-123 Battery Block 9 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3020-123 Battery Block 10 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3021-123 Battery Block 11 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3022-123 Battery Block 12 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3023-123 Battery Block 13 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3024-123 Battery Block 14 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on
P3025-123 Battery Block 15 Becomes Weak An internal malfunction of the HV battery is detected and the difference in voltage between each battery block or the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic)
  • Battery voltage sensor
  • HV battery
Comes on Master Warning Light:
Comes on

HINT: 

RELATED DATA LIST

DTC No. Data List
  • P3011-123
  • P3012-123
  • P3013-123
  • P3014-123
  • P3015-123
  • P3016-123
  • P3017-123
  • P3018-123
  • P3019-123
  • P3020-123
  • P3021-123
  • P3022-123
  • P3023-123
  • P3024-123
  • P3025-123
  • Internal Resistance R01 to R15
  • Battery Block Vol -V01 to V15

The following items can be helpful when performing repairs:

Data List 

Operation History Data