Power Source Mode does not Change to ON (IG) (07/2015 -): Procedure
- CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) - NO. 1 INTEGRATION RELAY)
- Disconnect the A36 certification ECU (smart key ECU assembly) connector.
- Disconnect the 1C and 1E No. 1 integration relay connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A36-9 (IG2D) - 1C-8 Always Below 1 Ω 1E-2 - Body ground Always Below 1 Ω A36-9 (IG2D) or 1C-8 - Body ground Always 10 kΩ or higher
Result: NG
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: OK
OK
See step 2
- INSPECT NO. 1 INTEGRATION RELAY (IG2 RELAY)
- Remove the No. 1 integration relay (Refer to REMOVAL (07/2015 -) ).
- Inspect the No. 1 integration relay (Refer to INSPECTION (07/2015 -) ).
Result: NG
NG
REPLACE NO. 1 INTEGRATION RELAY
(Refer to REMOVAL (07/2015 -) )
Result: OK
OK
See step 3
- CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the H56 certification ECU (smart key ECU assembly) connector.
- Disconnect the 3A instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H56-6 (IG1D) - 3A-27 Always Below 1 Ω 3B-7 - Body ground Always Below 1 Ω H56-6 (IG1D) and 3A-27 - Body ground Always 10 kΩ or higher
Result: NG
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: OK
OK
See step 4
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (IG1 NO. 1, IG1 NO. 2, IG1 NO. 3 AND IG1 NO. 4 RELAY)
- Remove the instrument panel junction block assembly (Refer to REMOVAL (07/2015 -) ).
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly (Refer to REMOVAL (07/2015 -) ).
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition - 3E-1 - 3D-33
(IG1 No. 1 relay)
- 3E-1 - 3D-36
(IG1 No. 2 relay)
- 3E-1 - 3C-4
(IG1 No. 3 relay)
- 3E-1 - 3C-14
(IG1 No. 4 relay)
Battery voltage not applied to terminals 3A-27 and 3B-7 10 kΩ or higher Battery voltage applied to terminals 3A-27 and 3B-7 Below 1 Ω - 3E-1 - 3D-33
Result: NG
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
(Refer to REMOVAL (07/2015 -) )
Result: OK
OK
See step 5
- CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
- Measure the voltage according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Component with harness connected
(Certification ECU (Smart Key ECU Assembly)- - Standard Voltage
Tester Connection Condition Specified Condition A36-9 (IG2D) - Body ground Engine switch on (ACC) → Engine switch on (IG) 1 V or less → 9 V or higher H56-6 (IG1D) - Body ground Engine switch on (ACC) → Engine switch on (IG) 1 V or less → 9 V or higher
Result: OK
OK
CHECK RELAY CONTACT SIDE CIRCUIT
Result: NG
NG
REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
(Refer to REMOVAL (07/2015 -) )
- Measure the voltage according to the value(s) in the table below.