Restraints Occupant Classification System Module Communication Stop Mode [05/2023 - ]: Procedure
- CHECK FOR OPEN IN CAN BUS WIRE (OCCUPANT DETECTION ECU BRANCH WIRE)
- Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.
- Disconnect the occupant detection ECU connector.
*a Front view of wire harness connector
(to Occupant Detection ECU) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition v15-5 (CANH) - v15-4 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω Result
Result OK NG
Result:
NG
REPLACE CAN BUS BRANCH WIRE AND CONNECTOR (OCCUPANT DETECTION ECU)
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
*a Front view of wire harness connector
(to Occupant Detection ECU)Standard Resistance
Tester Connection Condition Specified Condition v15-10 (GND) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω - Reconnect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition v15-6 (IG2) - Body ground Power switch on (IG) 11 to 14 V Power switch off Below 1 V Result
Result OK NG
Result:
OK
REPLACE OCCUPANT DETECTION ECU. Refer to REMOVAL [05/2023 - ]
Result:
NG
REPLACE HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.