Air Conditioning Control Panel does not Operate [08/2015 - 08/2021]: Procedure
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - NO. 2 AIR CONDITIONING CONTROL)
- Disconnect the G12 air conditioning amplifier assembly connector.
- Disconnect the T2 No. 2 air conditioning control assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G12-13 (RLIN) - T2-6 (RLIN) Always Below 1 Ω G12-13 (RLIN) or T2-6 (RLIN) - Body ground Always 10 kΩ or higher
Result:
OK
Go to AIR CONDITIONING SYSTEM
(Refer to PROBLEM SYMPTOMS TABLE [08/2015 - 08/2019] , or refer to PROBLEM SYMPTOMS TABLE [08/2019 - 08/2021] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR