DTC P2BF6: Exhaust Flow Control Valve "A" Position Circuit Low; DTC P2BF7: Exhaust Flow Control Valve "A" Position Circuit High; DTC P2BFE: Exhaust Flow Control Valve "B" Position Circuit Low; DTC P2BFF: Exhaust Flow Control Valve "B" Position Circuit High [05/2023 - ]: Description
Refer to DTC P26C6.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2BF6 | Exhaust Flow Control Valve "A" Position Circuit Low | The No. 1 exhaust pipe gas control actuator sub-assembly (opening angle sensor) output voltage is less than 0.08 V for 3 seconds or more (1 trip detection logic). |
|
Does not come on | DTC stored |
| P2BF7 | Exhaust Flow Control Valve "A" Position Circuit High | The No. 1 exhaust pipe gas control actuator sub-assembly (opening angle sensor) output voltage is higher than 4.73 V for 3 seconds or more (1 trip detection logic). |
|
Does not come on | DTC stored |
| P2BFE | Exhaust Flow Control Valve "B" Position Circuit Low | The No. 2 exhaust pipe gas control actuator sub-assembly (opening angle sensor) output voltage is less than 0.08 V for 3 seconds or more (1 trip detection logic). |
|
Does not come on | DTC stored |
| P2BFF | Exhaust Flow Control Valve "B" Position Circuit High | The No. 2 exhaust pipe gas control actuator sub-assembly (opening angle sensor) output voltage is higher than 4.73 V for 3 seconds or more (1 trip detection logic). |
|