Front Passenger Side Power Window Auto Up / Down Function does not Operate with Front Passenger Side Power Window Switch [12/2017 - 10/2023]: Procedure
- READ VALUE USING TECHSTREAM (P-DOOR MOTOR)
- Using the Techstream, read the data for the condition when the power window regulator switch assembly was operated.
Refer to DATA LIST / ACTIVE TEST [12/2017 - 10/2023]
Body Electrical > P-Door Motor > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note P Door P/W Auto SW Front passenger door power window auto switch signal OFF or ON OFF: Front passenger door power window auto switch not being operated
ON: Front passenger door power window auto switch being operated- Body Electrical > P-Door Motor > Data List
Tester Display P Door P/W Auto SW OK
On the Techstream screen, ON or OFF is displayed accordingly.
Result
Proceed to OK NG
Result:
NG
See step 3
Result:
OK
See step 2
- Using the Techstream, read the data for the condition when the power window regulator switch assembly was operated.
- PERFORM INITIALIZATION
- Initialize the front power window regulator motor assembly RH.
Refer to INITIALIZATION [12/2017 - 10/2023]
OK
Power window system operates normally.
Result
Proceed to OK NG
Result:
OK
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
NG
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH. Refer to REMOVAL [12/2017 - 09/2018] , or refer to REMOVAL [09/2018 - 10/2020] , or refer to REMOVAL [10/2020 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023]
- Initialize the front power window regulator motor assembly RH.
- INSPECT POWER WINDOW REGULATOR SWITCH ASSEMBLY
- Remove the power window regulator switch assembly.
Refer to REMOVAL [12/2017 - ]
- Inspect the power window regulator switch assembly.
Refer to INSPECTION [12/2017 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE POWER WINDOW REGULATOR SWITCH ASSEMBLY. Refer to REMOVAL [12/2017 - ]
Result:
OK
See step 4
- Remove the power window regulator switch assembly.
- CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR SWITCH ASSEMBLY - FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH)
- Disconnect the I1 power window regulator switch assembly connector.
- Disconnect the H2 front power window regulator motor assembly RH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I1-4 (AUTO) - H2-4 (AUTO) Always Below 1 Ω I1-4 (AUTO) or H2-4 (AUTO) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH. Refer to REMOVAL [12/2017 - 09/2018] , or refer to REMOVAL [09/2018 - 10/2020] , or refer to REMOVAL [10/2020 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR