Typical Malfunction Thresholds
CASE 1
| Following condition is met | 2 data or more |
| One of the following conditions (a), (b), (c) or (d) is met | More than 3 times |
| (a) Abnormal EEPROM access | Detected |
| (b) EEPROM communication timeout | Occurred |
| (c) Permanent Fault Code | Not stored |
| (d) Permanent Fault Code | Not equal to commanded Fault Code |
CASE 2
| Following condition is met | 2 data or more |
| One of the following conditions (a), (b) or (c) is met | More than 3 times |
| (a) Abnormal EEPROM access | Detected |
| (b) EEPROM communication timeout | Occurred |
| (c) Permanent Fault Code | Stored |
CASE 3
| Either of the following conditions is met | Condition (1) or (2) |
| (1) Following condition is met | 2 data or more |
| Either of the following conditions (a) or (b) is met | More than 3 times |
| (a) Abnormal EEPROM access | Detected |
| (b) EEPROM communication timeout | Occurred |
| (2) Permanent Fault Code data (more than 10 times) | Mismatch |