LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2019 >> NX 300 Base, AWD >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System - Diagnostics - Introduction >> Air Conditioning System >> Check Mode Procedure [10/2014 - 09/2017] >> Check Mode Procedure [10/2014 - 09/2017]
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Check Mode Procedure [10/2014 - 09/2017]

  1. REFRIGERANT GAS VOLUME CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC) 
    Fig 1: A/C Switch Indicator Remains On
    GTY498028Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    *a Example (for LHD)
    1. Start the engine.
    2. Check that A/C switch indicator remains on when the following conditions are met.
      MEASUREMENT CONDITION

      Item Condition
      A/C Switch On
      A/C operation time 15 minutes or more
      Ambient temperature* 0 to 49°C (32 to 120°F)
      Engine coolant temperature 45°C (113°F) or higher

      *: If the ambient temperature is not within the range shown, do not perform this check.

      HINT: 

      The A/C switch indicator and air conditioning system turn off if the amount of refrigerant in the system is insufficient.

    3. Connect the Techstream to the DLC3.
    4. Check for DTC B14B8.

      Body Electrical > Air Conditioner > Trouble Codes 

      RESULT

      Result Amount of Refrigerant Corrective Action
      DTC B14B8 is output Empty or nearly empty Check for refrigerant leaks using a halogen leak detector, and repair if necessary.
      Refer to REPLACEMENT [10/2014 - 07/2020]
      DTC B14B8 is not output Correct or insufficient Perform a refrigerant gas volume check using the Techstream.
  2. REFRIGERANT GAS VOLUME CHECK USING THE TECHSTREAM 
    1. Connect the Techstream to the DLC3.
    2. Start the engine.
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
    5. According to the display on the Techstream, perform the refrigerant gas volume check when the following conditions are met.
      MEASUREMENT CONDITION

      Item Condition
      A/C Switch On
      Ambient temperature* 0 to 49°C (32 to 120°F)
      R/F Switch Fresh (Ambient temperature is 31°C (87°F) or higher)
      Recirculation (Ambient temperature is 30°C (86°F) or less)
      Blower Speed HI

      () *: If the ambient temperature is not within the range shown, do not perform this check.

      Body Electrical > Air Conditioner > Utility 

      Tester Display
      Refrigerant Gas Volume Check

      HINT: 

      • Refer to the Techstream operator's manual for further details.
      • A message indicating a refrigerant gas volume is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
      • DTCs are not stored when performing the refrigerant gas volume check using the Techstream.
      RESULT

      Result Amount of Refrigerant Corrective Action
      Refrigerant shortage Insufficient or leakage
      1. Check for refrigerant leaks using a halogen leak detector, and repair if necessary.

        Refer to REPLACEMENT [10/2014 - 07/2020]

      2. Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.
      Refrigerant correct Correct -