Check Mode Procedure [10/2014 - 09/2017]
- REFRIGERANT GAS VOLUME CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC)
*a Example (for LHD) - Start the engine.
- Check that A/C switch indicator remains on when the following conditions are met.MEASUREMENT CONDITION
Item Condition A/C Switch On A/C operation time 15 minutes or more Ambient temperature* 0 to 49°C (32 to 120°F) Engine coolant temperature 45°C (113°F) or higher *: If the ambient temperature is not within the range shown, do not perform this check.
HINT:
The A/C switch indicator and air conditioning system turn off if the amount of refrigerant in the system is insufficient.
- Connect the Techstream to the DLC3.
- Check for DTC B14B8.
Body Electrical > Air Conditioner > Trouble Codes
RESULTResult Amount of Refrigerant Corrective Action DTC B14B8 is output Empty or nearly empty Check for refrigerant leaks using a halogen leak detector, and repair if necessary.
Refer to REPLACEMENT [10/2014 - 07/2020]DTC B14B8 is not output Correct or insufficient Perform a refrigerant gas volume check using the Techstream.
- REFRIGERANT GAS VOLUME CHECK USING THE TECHSTREAM
- Connect the Techstream to the DLC3.
- Start the engine.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
- According to the display on the Techstream, perform the refrigerant gas volume check when the following conditions are met.MEASUREMENT CONDITION
Item Condition A/C Switch On Ambient temperature* 0 to 49°C (32 to 120°F) R/F Switch Fresh (Ambient temperature is 31°C (87°F) or higher) Recirculation (Ambient temperature is 30°C (86°F) or less) Blower Speed HI () *: If the ambient temperature is not within the range shown, do not perform this check. Body Electrical > Air Conditioner > Utility
Tester Display Refrigerant Gas Volume Check HINT:
- Refer to the Techstream operator's manual for further details.
- A message indicating a refrigerant gas volume is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
- DTCs are not stored when performing the refrigerant gas volume check using the Techstream.
RESULTResult Amount of Refrigerant Corrective Action Refrigerant shortage Insufficient or leakage - Check for refrigerant leaks using a halogen leak detector, and repair if necessary.
Refer to REPLACEMENT [10/2014 - 07/2020]
- Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.
Refrigerant correct Correct -