DTC C1311-11: Open in Main Relay 1 Circuit; DTC C1312-12: Short in Main Relay 1 Circuit; DTC C1313-13: Open in Main Relay 2 Circuit; DTC C1314-14: Short in Main Relay 2 Circuit [10/2015 - 08/2018]: Description
The ABS main relay supplies power to the changeover solenoid and the linear solenoid.
The ABS main relay remains on for approximately 2 minutes after the power switch is turned off and the input of brake pedal operation signals stops, and supplies power to the system to keep it ready to operate.
| DTC No. | Detection Item | INF Code | DTC Detection Condition | Trouble Area | Note |
|---|---|---|---|---|---|
| C1311-11 | Open in Main Relay 1 Circuit | 1 | Either of the following is detected:
|
|
Electronically controlled brake system DTC |
| C1312-12 | Short in Main Relay 1 Circuit | 3 | The ABS main relay 1 contact is turned ON (BS01 terminal voltage 6.5 V or more) for 1 second or more when the ABS main relay 1 OFF is requested. |
|
Electronically controlled brake system DTC |
| C1313-13 | Open in Main Relay 2 Circuit | 4 | Either of the following is detected:
|
|
Electronically controlled brake system DTC |
| C1314-14 | Short in Main Relay 2 Circuit | 6 | The ABS main relay 2 contact is turned ON (BS02 terminal voltage 6.5 V or more) for 1 second or more when the ABS main relay 2 OFF is requested. |
|