Monitor Description
These DTCs are stored if an open or short in the EGR valve assembly circuit is detected.
Example:
- If the EGA+, EGA-, EGB+ or EGB- operation signal is off, but the step motor output signal is on, the ECM determines that there is a short in the EGR valve assembly circuit, and stores a DTC P040319 or P140019.
- If the EGA+, EGA-, EGB+ or EGB- operation signal is on, and the step motor output signal is off, the ECM determines that there is an open or short in the EGR valve assembly circuit, and stores a DTC P040318 or P140018.