DTC P3011-123: Battery Block 1 Becomes Weak; DTC P3012-123: Battery Block 2 Becomes Weak; DTC P3013-123: Battery Block 3 Becomes Weak; DTC P3014-123: Battery Block 4 Becomes Weak; DTC P3015-123: Battery Block 5 Becomes Weak; DTC P3016-123: Battery Block 6 Becomes Weak; DTC P3017-123: Battery Block 7 Becomes Weak; DTC P3018-123: Battery Block 8 Becomes Weak; DTC P3019-123: Battery Block 9 Becomes Weak; DTC P3020-123: Battery Block 10 Becomes Weak; DTC P3021-123: Battery Block 11 Becomes Weak; DTC P3022-123: Battery Block 12 Becomes Weak; DTC P3023-123: Battery Block 13 Becomes Weak; DTC P3024-123: Battery Block 14 Becomes Weak; DTC P3025-123: Battery Block 15 Becomes Weak; DTC P3026-123: Battery Block 16 Becomes Weak; DTC P3027-123: Battery Block 17 Becomes Weak [10/2014 - 09/2015]: Procedure
- CHECK DTC OUTPUT (HYBRID CONTROL)
Refer to PROCEDURE - Step 1
Result
Result Proceed to P0AFC-123 is not output. A P0AFC-123 is also output. B Result:
B
GO TO DTC CHART (P0AFC-123). Refer to DTC P0AFC-123: Hybrid Battery Pack Sensor Module [10/2014 - ]
Result:
A
See step 2
- READ VALUE USING TECHSTREAM (VB1 - VB17)
- Ensure the safety of the areas in front and at the back of the vehicle.
- Apply the parking brake and secure the wheels using chocks.
- Connect the Techstream to the DLC3.
- Turn the power switch on (READY).
- Fully warm up the engine and turn the air conditioning off.
- Enter the following menus: Powertrain / Hybrid Control / Data List / Battery Block Vol -V01 to V17.
- Firmly depress the brake pedal with your left foot.
- Move the shift lever to D.
- Record each battery block voltage from the Data List "Battery Block Vol -V01 to V17" while fully depressing the accelerator pedal.
Powertrain > Hybrid Control > Data List
Tester Display Battery Block Vol -V01 Battery Block Vol -V02 Battery Block Vol -V03 Battery Block Vol -V04 Battery Block Vol -V05 Battery Block Vol -V06 Battery Block Vol -V07 Battery Block Vol -V08 Battery Block Vol -V09 Battery Block Vol -V10 Battery Block Vol -V11 Battery Block Vol -V12 Battery Block Vol -V13 Battery Block Vol -V14 Battery Block Vol -V15 Battery Block Vol -V16 Battery Block Vol -V17 - Compare the battery block voltages "Battery Block Vol -V01 to V17" between the even and odd number groups in each combination shown in the tables below.TABLE 1
Circuit A Battery Block Circuit B Battery Block Condition Battery Block Vol -V01 (VB1) Battery Block Vol -V02 (VB2) "Battery Block Vol -V01" - "Battery Block Vol -V02" = 0.3 V or more Battery Block Vol -V04 (VB4) Battery Block Vol -V03 (VB3) "Battery Block Vol -V04" - "Battery Block Vol -V03" = 0.3 V or more Battery Block Vol -V05 (VB5) Battery Block Vol -V06 (VB6) "Battery Block Vol -V05" - "Battery Block Vol -V06" = 0.3 V or more Battery Block Vol -V08 (VB8) Battery Block Vol -V07 (VB7) "Battery Block Vol -V08" - "Battery Block Vol -V07" = 0.3 V or more Battery Block Vol -V09 (VB9) Battery Block Vol -V10 (VB10) "Battery Block Vol -V09" - "Battery Block Vol -V10" = 0.3 V or more Battery Block Vol -V12 (VB12) Battery Block Vol -V11 (VB11) "Battery Block Vol -V12" - "Battery Block Vol -V11" = 0.3 V or more Battery Block Vol -V13 (VB13) Battery Block Vol -V14 (VB14) "Battery Block Vol -V13" - "Battery Block Vol -V14" = 0.3 V or more Battery Block Vol -V16 (VB16) Battery Block Vol -V15 (VB15) "Battery Block Vol -V16" - "Battery Block Vol -V15" = 0.3 V or more Battery Block Vol -V17 (VB17) Battery Block Vol -V14 (VB14) "Battery Block Vol -V17" - "Battery Block Vol -V14" = 0.3 V or more TABLE 2Circuit A Battery Block Circuit B Battery Block Condition Battery Block Vol -V01 (VB1) Battery Block Vol -V02 (VB2) "Battery Block Vol -V02" - "Battery Block Vol -V01" = 0.3 V or more Battery Block Vol -V04 (VB4) Battery Block Vol -V03 (VB3) "Battery Block Vol -V03" - "Battery Block Vol -V04" = 0.3 V or more Battery Block Vol -V05 (VB5) Battery Block Vol -V06 (VB6) "Battery Block Vol -V06" - "Battery Block Vol -V05" = 0.3 V or more Battery Block Vol -V08 (VB8) Battery Block Vol -V07 (VB7) "Battery Block Vol -V07" - "Battery Block Vol -V08" = 0.3 V or more Battery Block Vol -V09 (VB9) Battery Block Vol -V10 (VB10) "Battery Block Vol -V10" - "Battery Block Vol -V09" = 0.3 V or more Battery Block Vol -V12 (VB12) Battery Block Vol -V11 (VB11) "Battery Block Vol -V11" - "Battery Block Vol -V12" = 0.3 V or more Battery Block Vol -V13 (VB13) Battery Block Vol -V14 (VB14) "Battery Block Vol -V14" - "Battery Block Vol -V13" = 0.3 V or more Battery Block Vol -V16 (VB16) Battery Block Vol -V15 (VB15) "Battery Block Vol -V15" - "Battery Block Vol -V16" = 0.3 V or more Battery Block Vol -V17 (VB17) Battery Block Vol -V14 (VB14) "Battery Block Vol -V14" - "Battery Block Vol -V17" = 0.3 V or more HINT:
Make sure to compare Battery Block Vol -V17 to Battery Block Vol -V14 in accordance with the tables above.
HINT:
When an internal malfunction occurs in the battery voltage sensor, this symptom (difference in voltage of 0.3 V or more for all 9 pairs of blocks) will occur.
Result
Result Proceed to All conditions in table 1 are met. A All conditions in table 2 are met. Other than above B - Turn the power switch off.
- Disconnect the Techstream from the DLC3.
Result:
A
REPLACE BATTERY VOLTAGE SENSOR. Refer to COMPONENTS [10/2014 - ]
Result:
B
See step 3
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Read output DTCs.
Powertrain > Hybrid Control > Trouble Codes
Result
Result Proceed to P3015-123 is not output. A P3015-123 is output. B HINT:
DTC P3015-123 may also be stored if there is foreign matter, etc. adhering to the connecting part of the service plug grip.
- Turn the power switch off.
- Disconnect the Techstream from the DLC3.
Result:
A
REPLACE HV BATTERY. Refer to COMPONENTS [10/2014 - 09/2015]
Result:
B
REPLACE HV BATTERY AND SERVICE PLUG GRIP. Refer to COMPONENTS [10/2014 - 09/2015]