| P033500 |
Crankshaft Position Sensor "A" |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0335-00: Crankshaft Position Sensor "A"; DTC P033531: Crankshaft Position Sensor "A" No Signal [10/2018 - ] |
| P033531 |
Crankshaft Position Sensor "A" No Signal |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0335-00: Crankshaft Position Sensor "A"; DTC P033531: Crankshaft Position Sensor "A" No Signal [10/2018 - ] |
| P034000 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0340-00: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor; DTC P034031: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal [10/2018 - ] |
| P034031 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0340-00: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor; DTC P034031: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal [10/2018 - ] |
| P062F44 |
Internal Control Module EEPROM Data Memory Failure |
Comes on |
Master Warning: Does not come on |
Refer to DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [10/2018 - ] |
| P062F46 |
Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P062F-46: Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure [10/2018 - ] |
| P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P06D61C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P0A0011 |
Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A0015: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [10/2018 - ] |
| P0A0015 |
Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A0015: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [10/2018 - ] |
| P0A001C |
Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A00-1C: Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range [10/2018 - ] |
| P0A0812 |
DC/DC Converter Status Circuit Short to Battery |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A08-12: DC/DC Converter Status Circuit Short to Battery; DTC P0A0814: DC/DC Converter Status Circuit Short to Ground or Open [10/2018 - ] |
| P0A0814 |
DC/DC Converter Status Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A08-12: DC/DC Converter Status Circuit Short to Battery; DTC P0A0814: DC/DC Converter Status Circuit Short to Ground or Open [10/2018 - ] |
| P0A1112 |
DC/DC Converter Enable Circuit Short to Battery |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A11-12: DC/DC Converter Enable Circuit Short to Battery; DTC P0A1114: DC/DC Converter Enable Circuit Short to Ground or Open [10/2018 - ] |
| P0A1114 |
DC/DC Converter Enable Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A11-12: DC/DC Converter Enable Circuit Short to Battery; DTC P0A1114: DC/DC Converter Enable Circuit Short to Ground or Open [10/2018 - ] |
| P0A1A47 |
Generator Control Module Watchdog / Safety μC Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P0A1A49 |
Generator Control Module Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P0A1B1F |
Generator Control Module Circuit Intermittent |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A1B-1F: Generator Control Module Circuit Intermittent [10/2018 - ] |
| P0A1C49 |
Drive Motor "B" Control Module Internal Electronic Failure |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A1C-49: Drive Motor "B" Control Module Internal Electronic Failure [10/2018 - ] |
| P0A3F16 |
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F1F: Drive Motor "A" Position Sensor Circuit Intermittent [10/2018 - ] |
| P0A3F1F |
Drive Motor "A" Position Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F1F: Drive Motor "A" Position Sensor Circuit Intermittent [10/2018 - ] |
| P0A3F21 |
Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [10/2018 - ] |
| P0A3F22 |
Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [10/2018 - ] |
| P0A4B16 |
Generator Position Sensor Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B1F: Generator Position Sensor Circuit Intermittent [10/2018 - ] |
| P0A4B1F |
Generator Position Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B1F: Generator Position Sensor Circuit Intermittent [10/2018 - ] |
| P0A4B21 |
Generator Position Sensor Signal Amplitude < Minimum |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A4B22: Generator Position Sensor Signal Amplitude > Maximum [10/2018 - ] |
| P0A4B22 |
Generator Position Sensor Signal Amplitude > Maximum |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A4B22: Generator Position Sensor Signal Amplitude > Maximum [10/2018 - ] |
| P0A6012 |
Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ] |
| P0A6014 |
Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ] |
| P0A601C |
Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ] |
| P0A601F |
Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ] |
| P0A6312 |
Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ] |
| P0A6314 |
Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ] |
| P0A631C |
Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ] |
| P0A631F |
Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ] |
| P0A7872 |
Drive Motor "A" Inverter Actuator Stuck Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A78-72: Drive Motor "A" Inverter Actuator Stuck Open [10/2018 - ] |
| P0A7873 |
Drive Motor "A" Inverter Actuator Stuck Closed |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A78-73: Drive Motor "A" Inverter Actuator Stuck Closed [10/2018 - ] |
| P0A789E |
Drive Motor "A" Inverter Stuck On |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D19: Drive Motor "A" Inverter Circuit Current Above Threshold [10/2018 - ] |
| P0A7A72 |
Generator Inverter Actuator Stuck Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A7A-72: Generator Inverter Actuator Stuck Open [10/2018 - ] |
| P0A7A73 |
Generator Inverter Actuator Stuck Closed |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A7A-73: Generator Inverter Actuator Stuck Closed [10/2018 - ] |
| P0A7A9E |
Generator Inverter Stuck On |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F19: Generator Inverter Circuit Current Above Threshold [10/2018 - ] |
| P0A9000 |
Drive Motor "A" Performance |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A90-00: Drive Motor "A" Performance [10/2018 - ] |
| P0A9200 |
Hybrid Generator Performance |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A92-00: Hybrid Generator Performance [10/2018 - ] |
| P0A949E |
DC/DC Converter Stuck On |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D3319: DC/DC Converter Circuit Current Above Threshold [10/2018 - ] |
| P0AED11 |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Refer to DTC P0AED-11: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground; DTC P0AED15: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open [10/2018 - ] |
| P0AED15 |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0AED-11: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground; DTC P0AED15: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open [10/2018 - ] |
| P0AED1C |
Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P0AED-1C: Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range [10/2018 - ] |
| P0BE512 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE514: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE51F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE912: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE914: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE91F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BE514 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE514: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE51F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE912: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE914: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE91F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BE51F |
Drive Motor "A" Phase U Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE514: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE51F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE912: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE914: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE91F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BE528 |
Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BE5-28: Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BE928: Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BED28: Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [10/2018 - ] |
| P0BE912 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE514: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE51F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE912: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE914: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE91F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BE914 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE514: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE51F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE912: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE914: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE91F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BE91F |
Drive Motor "A" Phase V Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE514: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE51F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE912: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE914: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE91F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BE928 |
Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BE5-28: Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BE928: Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BED28: Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [10/2018 - ] |
| P0BED12 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE514: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE51F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE912: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE914: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE91F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BED14 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE514: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE51F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE912: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE914: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE91F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BED1F |
Drive Motor "A" Phase W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE514: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE51F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE912: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE914: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE91F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BED28 |
Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BE5-28: Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BE928: Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BED28: Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [10/2018 - ] |
| P0BFD62 |
Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BFD-62: Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C671F: Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0BFF1D |
Drive Motor "A" Circuit Current Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P0BFF-1D: Drive Motor "A" Circuit Current Out of Range [10/2018 - ] |
| P0C1900 |
Drive Motor "A" Execution Torque Performance |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C19-00: Drive Motor "A" Execution Torque Performance [10/2018 - ] |
| P0C3811 |
DC/DC Converter Temperature Sensor "A" Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C3815: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [10/2018 - ] |
| P0C3815 |
DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C3815: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [10/2018 - ] |
| P0C381C |
DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C38-1C: DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range [10/2018 - ] |
| P0C3D11 |
DC/DC Converter Temperature Sensor "B" Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C3815: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [10/2018 - ] |
| P0C3D15 |
DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C3815: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [10/2018 - ] |
| P0C3D1C |
DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C3D-1C: DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range [10/2018 - ] |
| P0C5013 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C501F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [10/2018 - ] |
| P0C5016 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C5017: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [10/2018 - ] |
| P0C5017 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C5017: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [10/2018 - ] |
| P0C501F |
Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C501F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [10/2018 - ] |
| P0C5A13 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C501F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [10/2018 - ] |
| P0C5A16 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C5017: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [10/2018 - ] |
| P0C5A17 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C5017: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [10/2018 - ] |
| P0C5A1F |
Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C501F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [10/2018 - ] |
| P0C6413 |
Generator Position Sensor Circuit "A" Circuit Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C641F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C6913: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C691F: Generator Position Sensor Circuit "B" Circuit Intermittent [10/2018 - ] |
| P0C6416 |
Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C6417: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C6916: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C6917: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [10/2018 - ] |
| P0C6417 |
Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C6417: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C6916: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C6917: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [10/2018 - ] |
| P0C641F |
Generator Position Sensor Circuit "A" Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C641F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C6913: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C691F: Generator Position Sensor Circuit "B" Circuit Intermittent [10/2018 - ] |
| P0C6913 |
Generator Position Sensor Circuit "B" Circuit Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C641F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C6913: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C691F: Generator Position Sensor Circuit "B" Circuit Intermittent [10/2018 - ] |
| P0C6916 |
Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C6417: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C6916: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C6917: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [10/2018 - ] |
| P0C6917 |
Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C6417: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C6916: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C6917: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [10/2018 - ] |
| P0C691F |
Generator Position Sensor Circuit "B" Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C641F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C6913: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C691F: Generator Position Sensor Circuit "B" Circuit Intermittent [10/2018 - ] |
| P0C7917 |
Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0C79-17: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold [10/2018 - ] |
| P0CA300 |
DC/DC Converter Step Up Voltage Performance |
Comes on |
Master Warning: Comes on |
Refer to DTC P0CA3-00: DC/DC Converter Step Up Voltage Performance [10/2018 - ] |
| P0D2D16 |
Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold; DTC P0D2D17: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold; DTC P0D2D1F: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent [10/2018 - ] |
| P0D2D17 |
Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold; DTC P0D2D17: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold; DTC P0D2D1F: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent [10/2018 - ] |
| P0D2D1F |
Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold; DTC P0D2D17: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold; DTC P0D2D1F: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent [10/2018 - ] |
| P0D3319 |
DC/DC Converter Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D3319: DC/DC Converter Circuit Current Above Threshold [10/2018 - ] |
| P0DFA62 |
Generator Phase U-V-W Current Sensor Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P0DFA-62: Generator Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C691F: Generator Phase U-V-W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E0012 |
Generator Phase U Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E0014: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E001F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E0412: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E0414: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E041F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E0812: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E0814: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E081F: Generator Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E0014 |
Generator Phase U Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E0014: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E001F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E0412: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E0414: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E041F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E0812: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E0814: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E081F: Generator Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E001F |
Generator Phase U Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E0014: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E001F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E0412: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E0414: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E041F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E0812: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E0814: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E081F: Generator Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E0028 |
Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E0428: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E0828: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [10/2018 - ] |
| P0E0412 |
Generator Phase V Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E0014: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E001F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E0412: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E0414: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E041F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E0812: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E0814: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E081F: Generator Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E0414 |
Generator Phase V Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E0014: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E001F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E0412: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E0414: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E041F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E0812: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E0814: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E081F: Generator Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E041F |
Generator Phase V Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E0014: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E001F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E0412: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E0414: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E041F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E0812: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E0814: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E081F: Generator Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E0428 |
Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E0428: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E0828: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [10/2018 - ] |
| P0E0812 |
Generator Phase W Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E0014: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E001F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E0412: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E0414: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E041F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E0812: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E0814: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E081F: Generator Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E0814 |
Generator Phase W Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E0014: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E001F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E0412: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E0414: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E041F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E0812: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E0814: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E081F: Generator Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E081F |
Generator Phase W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E0014: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E001F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E0412: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E0414: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E041F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E0812: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E0814: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E081F: Generator Phase W Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E0828 |
Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E0428: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E0828: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [10/2018 - ] |
| P0E3116 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E3117: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E311F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [10/2018 - ] |
| P0E3117 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E3117: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E311F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [10/2018 - ] |
| P0E311F |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E3117: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E311F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [10/2018 - ] |
| P0E5111 |
DC/DC Converter Current Sensor Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E5115: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E511F: DC/DC Converter Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E5115 |
DC/DC Converter Current Sensor Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E5115: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E511F: DC/DC Converter Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E511F |
DC/DC Converter Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E5115: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E511F: DC/DC Converter Current Sensor Circuit Intermittent [10/2018 - ] |
| P0E5128 |
DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E51-28: DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [10/2018 - ] |
| P0E512A |
DC/DC Converter Current Sensor Signal Stuck In Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E51-2A: DC/DC Converter Current Sensor Signal Stuck In Range [10/2018 - ] |
| P0E5717 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E57-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold [10/2018 - ] |
| P0E5811 |
DC/DC Converter Temperature Sensor 2 Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E58-11: DC/DC Converter Temperature Sensor 2 Circuit Short to Ground; DTC P0E5815: DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open [10/2018 - ] |
| P0E5815 |
DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E58-11: DC/DC Converter Temperature Sensor 2 Circuit Short to Ground; DTC P0E5815: DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open [10/2018 - ] |
| P0E581C |
DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E58-1C: DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range [10/2018 - ] |
| P0E7100 |
Generator Execution Torque Performance |
Comes on |
Master Warning: Comes on |
Refer to DTC P0E71-00: Generator Execution Torque Performance [10/2018 - ] |
| P1C2A1C |
Generator A/D Converter Circuit Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P1C2A49 |
Generator A/D Converter Circuit Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P1C2B1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P1C2B49 |
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P1C2E46 |
Motor Generator ECU(EEPROM) Calibration / Parameter Memory Failure |
Does not come on |
Master Warning: Comes on |
Refer to DTC P1C2E-46: Motor Generator ECU(EEPROM) Calibration / Parameter Memory Failure [10/2018 - ] |
| P1C5D19 |
Drive Motor "A" Inverter Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D19: Drive Motor "A" Inverter Circuit Current Above Threshold [10/2018 - ] |
| P1C5F19 |
Generator Inverter Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Refer to DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F19: Generator Inverter Circuit Current Above Threshold [10/2018 - ] |
| P1C601F |
Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P1C621F |
Generator Control Module Offset Power Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P1C641F |
Generator Control Module Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C641F: Generator Control Module Circuit Intermittent; DTC P1CAF38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [10/2018 - ] |
| P1C651F |
Generator Control Module Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C651F: Generator Control Module Circuit Intermittent; DTC P1CB038: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [10/2018 - ] |
| P1C671F |
Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0BFD-62: Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C671F: Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent [10/2018 - ] |
| P1C691F |
Generator Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P0DFA-62: Generator Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C691F: Generator Phase U-V-W Current Sensor Circuit Intermittent [10/2018 - ] |
| P1CA51D |
Hybrid Generator Circuit Current Out of Range |
Comes on |
Master Warning: Comes on |
Refer to DTC P1CA5-1D: Hybrid Generator Circuit Current Out of Range [10/2018 - ] |
| P1CAC49 |
Generator Position Sensor Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C641F: Generator Control Module Circuit Intermittent; DTC P1CAF38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [10/2018 - ] |
| P1CAD49 |
Drive Motor "A" Position Sensor Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C651F: Generator Control Module Circuit Intermittent; DTC P1CB038: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [10/2018 - ] |
| P1CAF38 |
Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
Comes on |
Master Warning: Comes on |
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C641F: Generator Control Module Circuit Intermittent; DTC P1CAF38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [10/2018 - ] |
| P1CB038 |
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
Comes on |
Master Warning: Comes on |
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C651F: Generator Control Module Circuit Intermittent; DTC P1CB038: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [10/2018 - ] |
| P1CB59E |
DC/DC Converter Voltage Sensor "A"(VL) Stuck On |
Comes on |
Master Warning: Comes on |
Refer to DTC P1CB5-9E: DC/DC Converter Voltage Sensor "A"(VL) Stuck On [10/2018 - ] |
| P1CB69E |
Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
Comes on |
Master Warning: Comes on |
Refer to DTC P1CB6-9E: Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On [10/2018 - ] |
| P1CCC96 |
DC/DC Converter Enable Component Internal Failure |
Does not come on |
Master Warning: Comes on |
Refer to DTC P1CCC-96: DC/DC Converter Enable Component Internal Failure [10/2018 - ] |
| P1CFF62 |
Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Refer to DTC P1CFF-62: Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure [10/2018 - ] |
| P31241F |
Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P3124-1F: Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent; DTC P312487: Lost Communication between Drive Motor "A" and HV ECU Missing Message [10/2018 - ] |
| P312487 |
Lost Communication between Drive Motor "A" and HV ECU Missing Message |
Comes on |
Master Warning: Comes on |
Refer to DTC P3124-1F: Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent; DTC P312487: Lost Communication between Drive Motor "A" and HV ECU Missing Message [10/2018 - ] |
| P313383 |
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P313386 |
Communication Error from Generator to Drive Motor "A" Signal Invalid |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P313387 |
Communication Error from Generator to Drive Motor "A" Missing Message |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P313483 |
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P313486 |
Communication Error from Drive Motor "A" to Generator Signal Invalid |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P313487 |
Communication Error from Drive Motor "A" to Generator Missing Message |
Comes on |
Master Warning: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D61C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A49: Generator Control Module Internal Electronic Failure; DTC P1C2A1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C601F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C621F: Generator Control Module Offset Power Circuit Intermittent; DTC P313383: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P313386: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P313387: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P313483: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P313486: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P313487: Communication Error from Drive Motor "A" to Generator Missing Message [10/2018 - ] |
| P31481F |
Lost Communication between Drive Motor "A" and "B" Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Refer to DTC P3148-1F: Lost Communication between Drive Motor "A" and "B" Circuit Intermittent; DTC P314887: Lost Communication between Drive Motor "A" and "B" Missing Message [10/2018 - ] |
| P314887 |
Lost Communication between Drive Motor "A" and "B" Missing Message |
Does not come on |
Master Warning: Comes on |
Refer to DTC P3148-1F: Lost Communication between Drive Motor "A" and "B" Circuit Intermittent; DTC P314887: Lost Communication between Drive Motor "A" and "B" Missing Message [10/2018 - ] |
| P314F1F |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Comes on |
Master Warning: Comes on |
Refer to DTC P314F-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [10/2018 - ] |
| P31531D |
DC/DC Converter Current Sensor Circuit Current Out of Range |
Does not come on |
Master Warning: Comes on |
Refer to DTC P3153-1D: DC/DC Converter Current Sensor Circuit Current Out of Range [10/2018 - ] |
| U010087 |
Lost Communication With ECM/PCM "A" Missing Message |
Comes on |
Master Warning: Comes on |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U029387: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U117087: Lost Communication With Brake System Control Module(ch2) Missing Message [10/2018 - ] |
| U029387 |
Lost Communication With Hybrid Powertrain Control Module Missing Message |
Comes on |
Master Warning: Comes on |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U029387: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U117087: Lost Communication With Brake System Control Module(ch2) Missing Message [10/2018 - ] |
| U117087 |
Lost Communication With Brake System Control Module(ch2) Missing Message |
Comes on |
Master Warning: Comes on |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U029387: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U117087: Lost Communication With Brake System Control Module(ch2) Missing Message [10/2018 - ] |