DTC B1785: Front Occupant Classification Sensor LH Collision Detection [10/2018 - ]: Procedure
- PERFORM ZERO POINT CALIBRATION
- Using the Techstream, perform Zero Point Calibration.
Refer to INITIALIZATION [10/2018 - ]
OK
"Zero Point Calibration is complete." is displayed.
Result
Proceed to OK NG
Result:
NG
See step 5
Result:
OK
See step 2
- Using the Techstream, perform Zero Point Calibration.
- CHECK DTC
- Turn the ignition switch to ON, and wait for at least 60 seconds.
- Clear the DTCs stored in the occupant detection ECU.
Body Electrical > Occupant Detection > Clear DTCs
- Clear the DTCs stored in the airbag ECU assembly.
Body Electrical > SRS Airbag > Clear DTCs
- Turn the ignition switch off.
- Turn the ignition switch to ON, and wait for at least 10 seconds.
- Check for DTCs.
Body Electrical > Occupant Detection > Trouble Codes
OK
DTC B1785 is not output.
HINT:
Codes other than DTC B1785 may be output at this time, but they are not related to this check.
- Turn the ignition switch off.
Result
Proceed to OK NG
Result:
OK
END
Result:
NG
See step 3
- REPLACE FRONT SEAT ADJUSTER ASSEMBLY RH
- Turn the ignition switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Replace the front seat adjuster assembly RH.
Refer to DISASSEMBLY [10/2018 - ]
- Connect the cable to the negative (-) auxiliary battery terminal.
Result
Proceed to NEXT
Result:
NEXT
See step 4
- PERFORM ZERO POINT CALIBRATION
- Using the Techstream, perform Zero Point Calibration.
Refer to INITIALIZATION [10/2018 - ]
Result
Proceed to NEXT
Result:
NEXT
END
- Using the Techstream, perform Zero Point Calibration.
- REPLACE FRONT SEAT ADJUSTER ASSEMBLY RH
- Turn the ignition switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Replace the front seat adjuster assembly RH.
Refer to DISASSEMBLY [10/2018 - ]
- Connect the cable to the negative (-) auxiliary battery terminal.
Result
Proceed to NEXT
Result:
NEXT
See step 6
- PERFORM ZERO POINT CALIBRATION
- Using the Techstream, perform Zero Point Calibration.
Refer to INITIALIZATION [10/2018 - ]
Result
Proceed to NEXT
Result:
NEXT
END
- Using the Techstream, perform Zero Point Calibration.