Heated Oxygen Sensor
HEATED OXYGEN SENSOR
| Standard Resistance (for Bank 1) |
2 (HT1B) - 1 (+B) |
20°C (68°F) |
5 to 10 Ω |
| 2 (HT1B) - 3 (E2) |
Always |
10 kΩ or higher |
| Standard Resistance (for Bank 2) |
1 (HT2B) - 2 (+B) |
20°C (68°F) |
5 to 10 Ω |
| 1 (HT2B) - 4 (E2) |
Always |
10 kΩ or higher |