Service Data [06/2018 - 10/2019]: Relay
RELAY
| Standard Resistance (Main Relay (EFI-MAIN NO. 1)) |
3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (Main Relay (EFI-MAIN NO. 2)) |
3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (Main Relay (A/F HTR)) |
3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (Injector Relay (D INJ)) |
3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (VVT Relay (VVT)) |
3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (No. 2 ignition relay (IG2 NO. 1)) |
3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |