Home >> Lexus >> 2022 >> ES 350 Base >> Repair and Diagnosis (Single Page) >> Transmission >> Automatic Trans >> Automatic Transmission System (UA80E) - Diagnostic Codes (1 Of 3) >> Automatic Transaxle System >> DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [06/2018 - ] >> Typical Malfunction Thresholds
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Malfunction Thresholds

CASE 1

Following condition is met 2 data areas or more
Any of the following conditions (a), (b) or (c) are met More than 3 times
(a) EEPROM access error Occurred
(b) Permanent fault code Not stored
(c) Permanent fault code Not equal to commanded fault code
CASE 2

Following condition is met 2 data areas or more
Either of the following conditions (a) or (b) is met More than 3 times
(a) EEPROM access error Occurred
(b) Permanent fault code Stored
CASE 3

Either of the following conditions is met 1 or 2
1. Following condition is met 2 data areas or more
(a) EEPROM access error occurred More than 3 times