Home >> Lexus >> 2023 >> LX 600 Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (W/O Canister Pump Module) - Diagnostic Codes (3 Of 5) >> SFI SYSTEM (w/o Canister Pump Module) >> DTC P023A-14: Charge Air Cooler Coolant Pump Control Circuit Short to Ground or Open [12/2021 - ] >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P023A-14: Charge Air Cooler Coolant Pump Control Circuit Short to Ground or Open [12/2021 - ]: Procedure

  1. INSPECT ECM (INTERNAL CIRCUIT) 

    Pre-procedure1

    1. Disconnect the electric water pump assembly connector.

      Procedure1

    2. Measure the resistance according to the value(s) in the table below.

      Powertrain > Engine > Active Test 

      Tester Display
      Control the Intercooler Water Pump

      Standard Resistance

      Tester Connection Condition Specified Condition
      B29-3 (SWP) - Body ground Active Test OFF → ON Active Test OFF: Resistance stabilized → ON: Resistance changes*

      HINT: 

      *: The transistor inside the ECM performs duty control according to the Active Test being operated. The resistance of the SWP terminal changes while the Active Test is on due to duty control. If the resistance is stable while the Active Test is off and changes while the Active Test is on, the transistor is working correctly. If the transistor does not operate when the Active Test is on, there may be a malfunction in the ECM.

      Result

      Proceed to
      OK
      NG

      Post-procedure1

    3. None

    Result: 

    OK 

    REPLACE ELECTRIC WATER PUMP ASSEMBLY. Refer to  REMOVAL [12/2021 - ] 

    Result: 

    NG 

    See step  2

  2. CHECK HARNESS AND CONNECTOR (ELECTRIC WATER PUMP ASSEMBLY - ECM) 

    Pre-procedure1

    1. Disconnect the electric water pump assembly connector.
    2. Disconnect the ECM connector.

      Procedure1

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      B29-3 (SWP) - B70-37 (IWPO) Always Below 1 Ω
      B29-3 (SWP) or B70-37 (IWPO) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

      Post-procedure1

    4. None

    Result: 

    OK 

    REPLACE ECM. Refer to  REMOVAL [12/2021 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR