DTC P007A-15: Charge Air Cooler Temperature Sensor Bank 1 Circuit Short to Battery or Open [12/2021 - ]: Procedure
- READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)
Pre-procedure1
- Disconnect the No. 3 turbo pressure sensor connector.
*1 No. 3 Turbo Pressure Sensor *2 ECM *a Front view of wire harness connector
(to No. 3 Turbo Pressure Sensor) - Connect terminals 4 (THIM) and 2 (E2) of the No. 3 turbo pressure sensor connector on the wire harness side.
Procedure1
- Read the value displayed on the GTS.
Powertrain > Engine > Data List
Tester Display Intake Air Temperature B1S1 (Turbo) Result
Result Proceed to The value of Intake Air Temperature B1S1 (Turbo) is 140°C A None of the above conditions are met B HINT:
140°C (284°F)
Post-procedure1
- None
Result:
A
REPLACE NO. 3 TURBO PRESSURE SENSOR. Refer to REMOVAL [12/2021 - ]
Result:
B
See step 2
- Disconnect the No. 3 turbo pressure sensor connector.
- CHECK HARNESS AND CONNECTOR (NO. 3 TURBO PRESSURE SENSOR - ECM)
Pre-procedure1
- Disconnect the No. 3 turbo pressure sensor connector.
- Disconnect the ECM connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C40-4 (THIM) - C38-37 (THIM) Always Below 1 Ω C40-2 (E2) - C38-39 (EPIM) Always Below 1 Ω C40-4 (THIM) or C38-37 (THIM) - Other terminals Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE ECM. Refer to REMOVAL [12/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR