Front Height Control Sensor Sub-Assembly LH
FRONT HEIGHT CONTROL SENSOR SUB-ASSEMBLY LH
| Tester Connection |
Switch Condition |
Specified Condition |
| B-2 (SHFL) - B-1 (SHG) |
45° (High) |
4.00 to 4.10 V |
| B-2 (SHFL) - B-1 (SHG) |
0° (Standard position) |
2.20 to 2.30 V |
| B-2 (SHFL) - B-1 (SHG) |
-45° (Low) |
0.40 to 0.50 V |