DTC P007A-11: Charge Air Cooler Temperature Sensor Bank 1 Circuit Short to Ground [12/2021 - ]: Procedure
- READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
Pre-procedure1
- Disconnect the No. 3 turbo pressure sensor connector.
*1 No. 3 turbo pressure sensor *2 ECM Procedure1
- Read the value displayed on the GTS.
Powertrain > Engine > Data List
Tester Display Intake Air Temperature B1S1 (Turbo) Result
Result Proceed to The value of Intake Air Temperature B1S1 (Turbo) is -40°C A None of the above conditions are met B HINT:
-40°C (-40°F)
Post-procedure1
- None
Result:
A
REPLACE NO. 3 TURBO PRESSURE SENSOR. Refer to REMOVAL [12/2021 - ]
Result:
B
See step 2
- Disconnect the No. 3 turbo pressure sensor connector.
- CHECK HARNESS AND CONNECTOR (NO. 3 TURBO PRESSURE SENSOR - ECM)
Pre-procedure1
- Disconnect the No. 3 turbo pressure sensor connector.
- Disconnect the ECM connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C40-4 (THIM) or C38-37 (THIM) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE ECM. Refer to REMOVAL [12/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR