Front Auxiliary Control C938a
FRONT AUXILIARY CONTROL C938A CONNECTOR PINOUTS REFERENCE
| Pin Number(s) | Circuit Designation/Description | Normal Condition/Measurement |
|---|---|---|
| 1 | CKT 1131 (LG) front auxiliary controls to rear auxiliary controls | Resistance of 0 ohms to chassis ground with rear auxiliary control in FLOOR mode. |
| 2 | CKT 1128 (GY/LB) auxiliary mode door actuator feed | Greater than 10,000 ohms to chassis ground or 0 volts. |
| 3 | CKT 1125 (BN) auxiliary temperature blend door actuator return | Approximately 0-5 volts with the ignition on. |
| 4 | CKT 1129 (BN/WH) auxiliary mode door actuator return | Greater than 10,000 ohms to chassis ground or 0 volts. |
| 5 | CKT 1124 (WH) auxiliary temperature blend door actuator feed | Resistance of 0 ohms to chassis ground with rear auxiliary control in CEILING mode. |
| 7 | CKT 276 (BN) front auxiliary controls to rear auxiliary controls | Approximately 4,200 ohms to chassis ground. |
| 8 | CKT 1127 (YE) front auxiliary controls to rear auxiliary controls | Approximately 0-4,200 ohms to chassis ground. |
| 9 | CKT 1205 (BK) ground | Resistance of 0 ohms to chassis ground. |
| 10 | CKT 1003 (GY/YE) voltage in run | Greater than 10 volts with the ignition on. |