Electronic Automatic Temperature Control (EATC) Module and Electronic Manual Temperature Control (EMTC) Module Cold Boot Process
The purpose of the cold boot process is to allow the DATC/EATC or EMTC module to reinitialize and calibrate the actuators. To carry out the cold boot process, follow the steps below.
- Turn the ignition switch to the OFF position.
- Disconnect the DATC/EATC or EMTC module electrical connectors.
- Wait one minute.
- Connect the DATC/EATC or EMTC module electrical connectors.
- Turn the ignition switch to the ON position.
- Select any position except OFF on the DATC/EATC or EMTC module.
The DATC/EATC or EMTC module will now initialize and calibrate the actuators. Calibration of the actuators will take approximately 30 minutes.