Pinpoint Test E: The Sod-R Does Not Respond To The Scan Tool Or Cannot Be Configured
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
NOTE:
Failure to disconnect the battery when instructed will result in false resistance readings. Refer to
BATTERY, MOUNTING AND CABLES
.
- E1 VERIFY THE SOD-R PASS THE NETWORK TEST
- Enter the following diagnostic mode on the scan tool: Network Test.
- Using a scan tool, perform the network test.
Does the SOD-R pass the network test?
- Yes : The system is operating correctly at this time. The concern may have been caused by high network traffic or an intermittent problem.
- No : GO to E2 .
- E2 CHECK THE SOD-R ADDRESS GROUND CIRCUIT FOR AN OPEN
- Disconnect: Negative Battery Cable.
- Disconnect: SOD-R C4229 .
- Measure the resistance
between:
Positive Lead Negative Lead Pin Circuit Pin Circuit C4229-6 GD313 (BK/GN) - Ground
Is the resistance less than 3 ohms?
- Yes : CONFIGURE the SOD-R. REFER to MODULE CONFIGURATION .
- No : REPAIR the circuit.