Pinpoint Test M : DTC U1000:00 - RFA: Notes
Diagnostic Overview
DTC U1000:00 - RFA
Normal Operation and Fault Conditions
The RFA controls the output of several vehicle systems by means of solid state drivers. When an overload occurs on any of these drivers, a DTC sets. The RFA also tracks the number of repetitive faults on each of these circuits. The module compares this number of overloads to 3 progressive thresholds established for each circuit. At the each threshold, DTC U1000:00 sets along with the DTC associated with the affected circuit.
If the third threshold is exceeded, U3000:49 sets. U3000:49 cannot be cleared and the RFA will need to be replaced after the circuit fault is repaired. For more information on FET protection, refer to Module Controlled Functions .
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| U1000:00 | Solid State Driver Protection Activated-Driver Disabled: No Sub Type Information | Sets when the RFA has disabled a circuit due to a repetitive circuit overload and a progressive threshold is met. |
| U3000:49 | Control Module: Internal Electronic Failure | Sets when the RFA has disabled a circuit due to a repetitive circuit overload and a progressive threshold is met. This DTC cannot be cleared. |