Pinpoint Test N : The A/C Is Always On - A/C Mode Always Commanded On: Notes
Diagnostic Overview
Refer to Automatic Climate Control System for schematic and connector information.
Normal Operation and Fault Conditions
Voltage is provided to the A/C clutch relay coil and switch contacts. When A/C is requested and all conditions allow, a ground is provided to the A/C clutch relay coil from the PCM, energizing the A/C clutch relay. When the PCM energizes the relay, voltage is supplied to the A/C compressor clutch field coil from the relay. Ground is supplied for the A/C compressor clutch field coil.
An accurate evaporator temperature is critical for compressor engagement and the PCM uses the temperature measurement to turn the A/C compressor off before the evaporator temperatures are cold enough to freeze the condensation on the evaporator core.
When an A/C request is received by the PCM, the A/C compressor clutch only engages through the A/C clutch relay if all of the following conditions are met:
- The HVAC control module does not detect an evaporator temperature below approximately 1 °C (33.8 °F).
- The PCM does not detect excessively high or low refrigerant pressure from the A/C pressure transducer.
- The PCM does not detect excessively high engine coolant temperature.
- The PCM does not detect an ambient air temperature below approximately 0 °C (32 °F).
- The PCM does not detect a temperature sensor reading that does not correlate with the other temperature sensor readings.
- The PCM has not detected a WOT condition.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| P1464 | A/C Demand Out Of Self Test Range: No Sub Type Information | This DTC sets when the PCM senses an A/C request during a PCM self-test. |
Possible Sources
- Wiring, terminals or connectors
- FCIM
- PCM
- HVAC control module
Visual Inspection and Diagnostic Pre-checks
- Inspect loose or corroded PCM or HVAC control module connections.