Pinpoint Test E : The Sod-R Does Not Respond To The Scan Tool Or Cannot Be Configured
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
NOTE:
Failure to disconnect the battery when instructed will result in false resistance readings. Refer to Battery, Mounting and Cables
.
- E1 VERIFY THE SOD-R PASSES THE NETWORK TEST
- Using a scan tool, perform the network test.
Does the SOD-R pass the network test?
Yes The system is operating correctly at this time. The concern may have been caused by high network traffic or an intermittent problem. No GO to E2. - E2 CHECK THE SOD-R ADDRESS GROUND CIRCUIT FOR AN OPEN
- Disconnect: Negative Battery Cable.
- Disconnect: SOD-R C4229 .
- Measure the resistance
between:
Positive Lead Negative Lead Pin Circuit Pin Circuit C4229-6 GD351 (BK/GN) - Ground
Is the resistance less than 3 ohms?
Yes CONFIGURE the SOD-R. REFER to Module Configuration . No REPAIR the circuit.