LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lincoln >> 2018 >> MKZ Select, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 662 (Module Communications Network) >> Diagnosis And Testing >> Communications Network >> Pinpoint Tests >> Pinpoint Test I : The RHVAC (Rear Heating, Ventilation And Air Conditioning) Module Does Not Respond To The Diagnostic Scan Tool >> Pinpoint Test I : The RHVAC (Rear Heating, Ventilation And Air Conditioning) Module Does Not Respond To The Diagnostic Scan Tool
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Pinpoint Test I : The RHVAC (Rear Heating, Ventilation And Air Conditioning) Module Does Not Respond To The Diagnostic Scan Tool

WARNING: This page is about a different car, the 2017 Ford Police Interceptor Utility and 2017 Ford Explorer. However, it is still accessible from the selected car via links, so may be relevant.

  1. I1 CHECK THE RHVAC (REAR HEATING, VENTILATION AND AIR CONDITIONING) MODULE VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

    • Connect negative battery cable.
    • Ignition ON.
    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C3198-6
      GFD127556Courtesy of FORD MOTOR COMPANY
      Ground

    Is the voltage greater than 11 volts? 

    Yes  GO to  I2
    No  VERIFY the BCM fuse 11 (5A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the OEM WIRING DIAGRAMS to identify the possible causes of the circuit short.
  2. I2 CHECK THE RHVAC (REAR HEATING, VENTILATION AND AIR CONDITIONING) MODULE GROUND CIRCUIT FOR AN OPEN

    • Ignition OFF.
    • Disconnect negative battery cable.
    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C3198-5
      GFD127555Courtesy of FORD MOTOR COMPANY
      Ground

    Is the resistance less than 3 ohms? 

    Yes  CONNECT negative battery cable. GO to  I3
    No  REPAIR the circuit.
  3. I3 CHECK THE MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) CIRCUITS BETWEEN THE RHVAC (REAR HEATING, VENTILATION AND AIR CONDITIONING) MODULE AND THE GWM (GATEWAY MODULE A) FOR AN OPEN

    • Disconnect RHVAC module C3198 .
    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C3198-1
      GFD127555Courtesy of FORD MOTOR COMPANY
      C2431-23
      C3198-2
      GFD127555Courtesy of FORD MOTOR COMPANY
      C2431-22

    Are the resistances less than 3 ohms? 

    Yes  GO to  I4
    No  REPAIR the circuit in question.
  4. I4 CHECK FOR CORRECT RHVAC (REAR HEATING, VENTILATION AND AIR CONDITIONING) MODULE OPERATION

    • Ignition OFF.
    • Disconnect and inspect all the RHVAC module connectors and related in-line connectors.
    • Repair:
      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary
    • Reconnect the RHVAC module connectors and related in-line connectors. Make sure they seat and latch correctly.
    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new RHVAC module. REFER to: Rear Heating, Ventilation and Air Conditioning (RHVAC) Control Module .
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.