Pinpoint Test R : The DSP (Audio Digital Signal Processing Module) Does Not Respond To The Diagnostic Scan Tool
WARNING: This page is about a different car, the 2018 Ford F-550 Super Duty, 2018 Ford F-450 Super Duty, 2018 Ford F-350 Super Duty, and 2018 Ford F-250 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.
- R1 CHECK THE DSP (AUDIO DIGITAL SIGNAL PROCESSING MODULE) VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: DSP C3154C .
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C3154C-5 Ground
Is the voltage greater than 11 volts?
Yes GO to R2 No VERIFY BCM fuse 28 (20A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the OEM Wiring Diagrams to identify the possible causes of the circuit short. - R2 CHECK THE DSP (AUDIO DIGITAL SIGNAL PROCESSING MODULE) GROUND CIRCUIT FOR AN OPEN
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead C3154C-13 Ground
Is the resistance less than 3 ohms?
Yes GO to R3 No REPAIR the circuit. - R3 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) CIRCUITS BETWEEN THE DSP (AUDIO DIGITAL SIGNAL PROCESSING MODULE) AND THE GWM (GATEWAY MODULE A) FOR AN OPEN
- Disconnect: GWM C2431
- Disconnect: DSP C3154A
Are the resistances less than 3 ohms?
Yes GO to R4 No REPAIR the circuit in question. - R4 CHECK FOR CORRECT DSP (AUDIO DIGITAL SIGNAL PROCESSING MODULE) OPERATION
- Ignition OFF.
- Disconnect and inspect the DSP connector and related in-line connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the DSP connector and related in-line connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new DSP. Refer to: Audio Digital Signal Processing (DSP) Module . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.