Pinpoint Test R : The Image Processing Module A (IPMA) Does Not Respond To The Diagnostic Scan Tool
WARNING: This page is about a different car, the 2018 Lincoln Continental. However, it is still accessible from the selected car via links, so may be relevant.
- R1 CHECK THE IPMA (IMAGE PROCESSING MODULE A) VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: IPMA C9012 .
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C9012-1 Ground
Is the voltage greater than 11 volts?
Yes GO to R2 No VERIFY the BCM fuse 36 (15A) is OK. If OK, REPAIR the circuit. If not OK, REFER to OEM ELECTRICAL WIRING DIAGRAM INTRODUCTION to identify the possible causes of the circuit short. - R2 CHECK THE IPMA (IMAGE PROCESSING MODULE A) GROUND CIRCUIT FOR AN OPEN
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead C9012-8 Ground
Is the resistance less than 3 ohms?
Yes GO to R3 No REPAIR the circuit. - R3 CHECK THE HS-CAN2 (HIGH SPEED-CONTROLLER AREA NETWORK 2) CIRCUITS BETWEEN THE IPMA (IMAGE PROCESSING MODULE A) AND THE DLC (DATA LINK CONNECTOR) FOR AN OPEN
Are the resistances less than 3 ohms?
Yes GO to R4 No REPAIR the circuit in question. - R4 CHECK FOR CORRECT IPMA (IMAGE PROCESSING MODULE A) OPERATION
- Ignition OFF.
- Disconnect and inspect the IPMA connector and related in-line connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPMA connector and related in-line connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new IPMA. Refer to: Interior Rear View Mirror . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.