Climate Control System DTCS
Diagnostics in this information assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods .
| Module | DTC | Description | Action |
|---|---|---|---|
| ACCM | B11EE:19 | A/C Compressor: Circuit Current Above Threshold | GO to Pinpoint Test AL |
| ACCM | B11EE:41 | A/C Compressor: General Checksum Failure | GO to Pinpoint Test AU |
| ACCM | B11EE:4B | A/C Compressor: Over Temperature | GO to Pinpoint Test AL |
| ACCM | B11EE:92 | A/C Compressor: Performance Or Incorrect Operation | GO to Pinpoint Test AL |
| ACCM | P0562:00 | System Voltage Low: No Sub Type Information | GO to Pinpoint Test AL |
| ACCM | P0563:00 | System Voltage High: No Sub Type Information | GO to Pinpoint Test AL |
| ACCM | P0AFA:16 | Hybrid/EV Battery System Voltage Low: Circuit Voltage Below Threshold | GO to Pinpoint Test AL |
| ACCM | P0AFB:17 | Hybrid/EV Battery System Voltage High: Circuit Voltage Above Threshold | GO to Pinpoint Test AL |
| ACCM | P0AFB:1C | Hybrid/EV Battery System Voltage High: Circuit Voltage Out Of Range | GO to Pinpoint Test AL |
| ACCM | U0001:88 | High Speed CAN Communication Bus: Bus Off | GO to Pinpoint Test AR |
| ACCM | U0100:00 | Lost Communication With ECM/PCM 'A': No Sub Type Information | GO to Pinpoint Test AN |
| ACCM | U0111:00 | Lost Communication With Battery Energy Control Module 'A': No Sub Type Information | GO to Pinpoint Test AO |
| ACCM | U0140:00 | Lost Communication With Body Control Module: No Sub Type Information | GO to Pinpoint Test P |
| ACCM | U3000:04 | Control Module: System Internal Failure | GO to Pinpoint Test AU |
| ACCM | U3000:42 | Control Module: General Memory Failure | GO to Pinpoint Test AU |
| ACCM | U3000:49 | Control Module: Internal Electronic Failure | GO to Pinpoint Test AU |
| BCMC | B3A01:00 | A/C Refrigerant Distribution Valve Actuator 'C' Control Circuit/Open: No Sub Type Information | GO to Pinpoint Test AX |
| BCMC | B3A02:00 | A/C Refrigerant Distribution Valve Actuator 'C' Control Circuit Low: No Sub Type Information | GO to Pinpoint Test AX |
| BCMC | B3A03:00 | A/C Refrigerant Distribution Valve Actuator 'C' Control Circuit High: No Sub Type Information | GO to Pinpoint Test AX |
| BCMC | P2611:00 | A/C Refrigerant Distribution Valve 'A' Control Circuit/Open: No Sub Type Information | GO to Pinpoint Test AV |
| BCMC | P2612:00 | A/C Refrigerant Distribution Valve 'A' Control Circuit Low: No Sub Type Information | GO to Pinpoint Test AV |
| BCMC | P2613:00 | A/C Refrigerant Distribution Valve 'A' Control Circuit High: No Sub Type Information | GO to Pinpoint Test AV |
| BCMC | P2CFC:00 | A/C Clutch Control Circuit: No Sub Type Information | GO to Pinpoint Test C |
| BCMC | P2CFD:00 | A/C Clutch Control Circuit Low: No Sub Type Information | GO to Pinpoint Test C |
| BCMC | P2CFE:00 | A/C Clutch Control Circuit High: No Sub Type Information | GO to Pinpoint Test C |
| BCMC | P2E62:00 | Engine Coolant Bypass Valve 'E' Control Circuit/Open: No Sub Type Information | GO to Pinpoint Test AW |
| BCMC | P2E63:00 | Engine Coolant Bypass Valve 'E' Control Circuit Low: No Sub Type Information | GO to Pinpoint Test AW |
| BCMC | P2E64:00 | Engine Coolant Bypass Valve 'E' Control Circuit High: No Sub Type Information | GO to Pinpoint Test AW |
| HVAC | B102E:11 | Air Quality Sensor: Circuit Short To Ground | GO to Pinpoint Test Y |
| HVAC | B102E:15 | Air Quality Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test Y |
| HVAC | B102E:92 | Air Quality Sensor: Performance Or Incorrect Operation | GO to Pinpoint Test Y |
| HVAC | B1081:07 | Left Temperature Damper Motor: Mechanical Failure | GO to Pinpoint Test G |
| HVAC | B1081:11 | Left Temperature Damper Motor: Circuit Short To Ground | GO to Pinpoint Test G |
| HVAC | B1081:12 | Left Temperature Damper Motor: Circuit Short To Battery | GO to Pinpoint Test G |
| HVAC | B1081:13 | Left Temperature Damper Motor: Circuit Open | GO to Pinpoint Test G |
| HVAC | B1082:07 | Right Temperature Damper Motor: Mechanical Failure | GO to Pinpoint Test H |
| HVAC | B1082:11 | Right Temperature Damper Motor: Circuit Short To Ground | GO to Pinpoint Test H |
| HVAC | B1082:12 | Right Temperature Damper Motor: Circuit Short To Battery | GO to Pinpoint Test H |
| HVAC | B1082:13 | Right Temperature Damper Motor: Circuit Open | GO to Pinpoint Test H |
| HVAC | B1083:07 | Recirculation Damper Motor: Mechanical Failure | GO to Pinpoint Test I |
| HVAC | B1083:11 | Recirculation Damper Motor: Circuit Short To Ground | GO to Pinpoint Test I |
| HVAC | B1083:12 | Recirculation Damper Motor: Circuit Short To Battery | GO to Pinpoint Test I |
| HVAC | B1083:13 | Recirculation Damper Motor: Circuit Open | GO to Pinpoint Test I |
| HVAC | B1086:07 | Air Distribution Damper Motor: Mechanical Failure | GO to Pinpoint Test J |
| HVAC | B1086:11 | Air Distribution Damper Motor: Circuit Short To Ground | GO to Pinpoint Test J |
| HVAC | B1086:12 | Air Distribution Damper Motor: Circuit Short To Battery | GO to Pinpoint Test J |
| HVAC | B1086:13 | Air Distribution Damper Motor: Circuit Open | GO to Pinpoint Test J |
| HVAC | B10AF:11 | Blower Fan Relay: Circuit Short To Ground | GO to Pinpoint Test N |
| HVAC | B10AF:15 | Blower Fan Relay: Circuit Short To Battery Or Open | GO to Pinpoint Test N |
| HVAC | B10AF:15 | Blower Fan Relay: Circuit Short To Battery Or Open | GO to Pinpoint Test O |
| HVAC | B10B3:11 | Right Panel Air Discharge Temperature: Circuit Short To Ground | GO to Pinpoint Test AA |
| HVAC | B10B3:15 | Right Panel Air Discharge Temperature: Circuit Short To Battery Or Open | GO to Pinpoint Test AA |
| HVAC | B10B4:11 | Right Floor Air Discharge Temperature: Circuit Short To Ground | GO to Pinpoint Test AA |
| HVAC | B10B4:15 | Right Floor Air Discharge Temperature: Circuit Short To Battery Or Open | GO to Pinpoint Test AA |
| HVAC | B10B5:11 | Left Panel Air Discharge Temperature: Circuit Short To Ground | GO to Pinpoint Test AA |
| HVAC | B10B5:15 | Left Panel Air Discharge Temperature: Circuit Short To Battery Or Open | GO to Pinpoint Test AA |
| HVAC | B10B6:11 | Left Floor Air Discharge Temperature: Circuit Short To Ground | GO to Pinpoint Test AA |
| HVAC | B10B6:15 | Left Floor Air Discharge Temperature: Circuit Short To Battery Or Open | GO to Pinpoint Test AA |
| HVAC | B10B7:11 | Rear Air Discharge Temperature: Circuit Short To Ground | GO to Pinpoint Test AG |
| HVAC | B10B7:15 | Rear Air Discharge Temperature: Circuit Short To Battery Or Open | GO to Pinpoint Test AG |
| HVAC | B10B9:12 | Blower Control: Circuit Short To Battery | GO to Pinpoint Test N |
| HVAC | B10B9:14 | Blower Control: Circuit Short To Ground Or Open | GO to Pinpoint Test N |
| HVAC | B10BA:12 | Rear Blower Control: Circuit Short To Battery | GO to Pinpoint Test AZ |
| HVAC | B10BA:14 | Rear Blower Control: Circuit Short To Ground Or Open | GO to Pinpoint Test AZ |
| HVAC | B11E3:07 | Rear HVAC Damper Motor: Mechanical Failure | GO to Pinpoint Test AG |
| HVAC | B11E3:11 | Rear HVAC Damper Motor: Circuit Short To Ground | GO to Pinpoint Test AG |
| HVAC | B11E3:12 | Rear HVAC Damper Motor: Circuit Short To Battery | GO to Pinpoint Test AG |
| HVAC | B11E3:13 | Rear HVAC Damper Motor: Circuit Open | GO to Pinpoint Test AG |
| HVAC | B11E4:07 | Rear Air Distribution Damper Motor: Mechanical Failure | GO to Pinpoint Test AI |
| HVAC | B11E4:11 | Rear Air Distribution Damper Motor: Circuit Short To Ground | GO to Pinpoint Test AI |
| HVAC | B11E4:12 | Rear Air Distribution Damper Motor: Circuit Short To Battery | GO to Pinpoint Test AI |
| HVAC | B11E4:13 | Rear Air Distribution Damper Motor: Circuit Open | GO to Pinpoint Test AI |
| HVAC | B11E5:11 | Left HVAC Damper Position Sensor: Circuit Short To Ground | GO to Pinpoint Test G |
| HVAC | B11E5:15 | Left HVAC Damper Position Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test G |
| HVAC | B11E6:11 | Right HVAC Damper Position Sensor: Circuit Short To Ground | GO to Pinpoint Test H |
| HVAC | B11E6:15 | Right HVAC Damper Position Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test H |
| HVAC | B11E7:11 | Air Distribution Damper Position Sensor: Circuit Short To Ground | GO to Pinpoint Test J |
| HVAC | B11E7:15 | Air Distribution Damper Position Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test J |
| HVAC | B11EC:12 | Rear HVAC Blower Control Input: Circuit Short To Battery | GO to Pinpoint Test AD |
| HVAC | B11EC:14 | Rear HVAC Blower Control Input: Circuit Short To Ground Or Open | GO to Pinpoint Test AD |
| HVAC | B11F0:11 | Air Intake Damper Position Sensor: Circuit Short To Ground | GO to Pinpoint Test I |
| HVAC | B11F0:15 | Air Intake Damper Position Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test I |
| HVAC | B1364:07 | Left Rear Temperature Damper Motor: Mechanical Failure | GO to Pinpoint Test AJ |
| HVAC | B1364:11 | Left Rear Temperature Damper Motor: Circuit Short To Ground | GO to Pinpoint Test AJ |
| HVAC | B1364:12 | Left Rear Temperature Damper Motor: Circuit Short To Battery | GO to Pinpoint Test AJ |
| HVAC | B1364:13 | Left Rear Temperature Damper Motor: Circuit Open | GO to Pinpoint Test AJ |
| HVAC | B1379:11 | Rear Cabin Temperature Sensor: Circuit Short To Ground | GO to Pinpoint Test BD |
| HVAC | B1379:15 | Rear Cabin Temperature Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test BD |
| HVAC | B14D3:11 | Left Rear Panel Discharge Sensor: Circuit Short To Ground | GO to Pinpoint Test BC |
| HVAC | B14D3:15 | Left Rear Panel Discharge Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test BC |
| HVAC | B14D4:11 | Left Rear Floor Discharge Sensor: Circuit Short To Ground | GO to Pinpoint Test BC |
| HVAC | B14D4:15 | Left Rear Floor Discharge Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test BC |
| HVAC | B1580:11 | Console Airflow Shut Off Door Position Sensor: Circuit Short To Ground | GO to Pinpoint Test BB |
| HVAC | B1580:15 | Console Airflow Shut Off Door Position Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test BB |
| HVAC | B1581:07 | Console Airflow Shut Off Door Damper Motor: Mechanical Failure | GO to Pinpoint Test BB |
| HVAC | B1581:11 | Console Airflow Shut Off Door Damper Motor: Circuit Short To Ground | GO to Pinpoint Test BB |
| HVAC | B1581:12 | Console Airflow Shut Off Door Damper Motor: Circuit Short To Battery | GO to Pinpoint Test BB |
| HVAC | B1581:13 | Console Airflow Shut Off Door Damper Motor: Circuit Open | GO to Pinpoint Test BB |
| HVAC | B1582:11 | Left Panel Discharge Sensor #3: Circuit Short To Ground | GO to Pinpoint Test BC |
| HVAC | B1582:15 | Left Panel Discharge Sensor #3: Circuit Short To Battery Or Open | GO to Pinpoint Test BC |
| HVAC | B158C:11 | Air Distribution Damper Position Sensor #3: Circuit Short To Ground | GO to Pinpoint Test AF |
| HVAC | B158C:15 | Air Distribution Damper Position Sensor #3: Circuit Short To Battery Or Open | GO to Pinpoint Test AF |
| HVAC | B158F:11 | Left HVAC Damper Position Sensor #3: Circuit Short To Ground | GO to Pinpoint Test AJ |
| HVAC | B158F:15 | Left HVAC Damper Position Sensor #3: Circuit Short To Battery Or Open | GO to Pinpoint Test AJ |
| HVAC | B159B:11 | Cabin Temperature Sensor #3: Circuit Short To Ground | GO to Pinpoint Test BD |
| HVAC | B159B:15 | Cabin Temperature Sensor #3: Circuit Short To Battery Or Open | GO to Pinpoint Test BD |
| HVAC | B159E:07 | Air Distribution Damper Motor #3: Mechanical Failure | GO to Pinpoint Test AF |
| HVAC | B159E:11 | Air Distribution Damper Motor #3: Circuit Short To Ground | GO to Pinpoint Test AF |
| HVAC | B159E:12 | Air Distribution Damper Motor #3: Circuit Short To Battery | GO to Pinpoint Test AF |
| HVAC | B159E:13 | Air Distribution Damper Motor #3: Circuit Open | GO to Pinpoint Test AF |
| HVAC | B1A61:11 | Cabin Temperature Sensor: Circuit Short To Ground | GO to Pinpoint Test E |
| HVAC | B1A61:15 | Cabin Temperature Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test E |
| HVAC | B1A63:11 | Right Solar Sensor: Circuit Short To Ground | GO to Pinpoint Test Z |
| HVAC | B1A63:15 | Right Solar Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test Z |
| HVAC | B1A64:11 | Left Solar Sensor: Circuit Short To Ground | GO to Pinpoint Test Z |
| HVAC | B1A64:15 | Left Solar Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test Z |
| HVAC | B1A69:11 | Humidity Sensor: Circuit Short To Ground | GO to Pinpoint Test E |
| HVAC | B1A69:15 | Humidity Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test E |
| HVAC | B1B71:11 | Evaporator Temperature Sensor: Circuit Short To Ground | GO to Pinpoint Test F |
| HVAC | B1B71:15 | Evaporator Temperature Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test F |
| HVAC | B1B7D:11 | Rear Air Distribution Actuator: Circuit Short To Ground | GO to Pinpoint Test AI |
| HVAC | B1B7D:15 | Rear Air Distribution Actuator: Circuit Short To Battery Or Open | GO to Pinpoint Test AI |
| HVAC | C1B14:11 | Sensor Supply Voltage A: Circuit Short To Ground | GO to Pinpoint Test AC |
| HVAC | C1B14:12 | Sensor Supply Voltage A: Circuit Short To Battery | GO to Pinpoint Test AC |
| HVAC | P24AE:09 | Particulate Matter Sensor Circuit: Component Failure | GO to Pinpoint Test AY |
| HVAC | P24AE:8F | Particulate Matter Sensor Circuit: Erratic | GO to Pinpoint Test AY |
| HVAC | P24AE:92 | Particulate Matter Sensor Circuit: Performance Or Incorrect Operation | GO to Pinpoint Test AY |
| HVAC | U0140:00 | Lost Communication With Body Control Module: No Sub Type Information | GO to Pinpoint Test P |
| HVAC | U0155:00 | Lost Communication With Instrument Panel Cluster (IPC) Control Module: No Sub Type Information | GO to Pinpoint Test Q |
| HVAC | U0165:00 | Lost Communication With HVAC Control Module - Rear: No Sub Type Information | GO to Pinpoint Test S |
| HVAC | U0249:00 | Lost Communication With Entertainment Control Module -Rear 'B': No Sub Type Information | GO to Pinpoint Test T |
| HVAC | U0253:00 | Lost Communication With Accessory Protocol Interface Module: No Sub Type Information | GO to Pinpoint Test V |
| HVAC | U025D:00 | Lost Communication With Front Controls Interface Module 'B': No Sub Type Information | GO to Pinpoint Test W |
| HVAC | U0401:00 | Invalid Data Received from ECM/PCM A: No Sub Type Information | GO to Pinpoint Test AS |
| HVAC | U0401:82 | Invalid Data Received from ECM/PCM A: Alive/Sequence Counter Incorrect/Not Updated | GO to Pinpoint Test AS |
| HVAC | U0422:68 | Invalid Data Received From Body Control Module: Event Information | GO to Pinpoint Test AS |
| HVAC | U0422:81 | Invalid Data Received From Body Control Module: Invalid Serial Data Received | GO to Pinpoint Test AS |
| HVAC | U0452:00 | Invalid Data Received From Restraints Control Module: No Sub Type Information | GO to Pinpoint Test AS |
| HVAC | U054A:68 | Invalid Data Received From Entertainment Control Module-Rear 'B': Event Information | GO to Pinpoint Test AS |
| HVAC | U055E:68 | Invalid Data Received From Front Controls Interface Module 'B': Event Information | GO to Pinpoint Test AS |
| HVAC | U1000:00 | Solid State Driver Protection Active -Driver Disabled: No Sub Type Information | GO to Pinpoint Test X |
| HVAC | U2024:51 | Control Module Cal-Config Data: Not Programmed | GO to Pinpoint Test AT |
| HVAC | U2100:00 | Initial Configuration Not Complete: No Sub Type Information | GO to Pinpoint Test AT |
| HVAC | U3000:49 | Control Module: Internal Electronic Failure | GO to Pinpoint Test AU |
| HVAC | U3003:16 | Battery Voltage: Circuit Voltage Below Threshold | GO to Pinpoint Test AP |
| HVAC | U3003:17 | Battery Voltage: Circuit Voltage Above Threshold | GO to Pinpoint Test AQ |
| PCM | P0532:00 | A/C Refrigerant Pressure Sensor 'A' Circuit Low: No Sub Type Information | GO to Pinpoint Test A |
| PCM | P0533:00 | A/C Refrigerant Pressure Sensor 'A' Circuit High: No Sub Type Information | GO to Pinpoint Test A |
| PCM | P0645:00 | A/C Clutch Relay Control Circuit: No Sub Type Information | GO to Pinpoint Test B |
| PCM | P06A0:00 | Variable A/C Compressor Control Circuit: No Sub Type Information | GO to Pinpoint Test D |
| PCM | P1464:00 | A/C Demand Out Of Self Test Range: No Sub Type Information | GO to Pinpoint Test M |
| PCM | P193E:00 | A/C Clutch Request Signal: No Sub Type Information | GO to Pinpoint Test AB |
| PCM | P2183:00 | Engine Coolant Temperature Sensor 2 Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test BE |
| PCM | P2184:00 | Engine Coolant Temperature Sensor 2 Circuit Low: No Sub Type Information | GO to Pinpoint Test BE |
| PCM | P2185:00 | Engine Coolant Temperature Sensor 2 Circuit High: No Sub Type Information | GO to Pinpoint Test BE |
| PCM | P2186:00 | Engine Coolant Temperature Sensor 2 Circuit Intermittent/Erratic: No Sub Type Information | GO to Pinpoint Test BE |
| PCM | P2600:00 | Coolant Pump 'A' Control Circuit/Open: No Sub Type Information | GO to Pinpoint Test AH |
| PCM | P2601:00 | Coolant Pump 'A' Control Circuit Performance/Stuck Off: No Sub Type Information | GO to Pinpoint Test AH |
| PCM | P2602:00 | Coolant Pump 'A' Control Circuit Low: No Sub Type Information | GO to Pinpoint Test AH |
| PCM | P2603:00 | Coolant Pump 'A' Control Circuit High: No Sub Type Information | GO to Pinpoint Test AH |
| PCM | P26BE:00 | Engine Coolant Bypass Valve 'D' Control Circuit Low: No Sub Type Information | GO to Pinpoint Test BJ |
| PCM | P26BF:00 | Engine Coolant Bypass Valve 'D' Control Circuit High: No Sub Type Information | GO to Pinpoint Test BJ |
| RHVAC | B10B8:63 | Push Buttons: Circuit/Component Protection Time-Out | GO to Pinpoint Test AK |
| RHVAC | U0140:00 | Lost Communication With Body Control Module: No Sub Type Information | GO to Pinpoint Test P |
| RHVAC | U0164:00 | Lost Communication With HVAC Control Module 'A': No Sub Type Information | GO to Pinpoint Test R |
| RHVAC | U0247:00 | Lost Communication With Seat Control Module 'F': No Sub Type Information | GO to Pinpoint Test U |
| RHVAC | U0422:68 | Invalid Data Received From Body Control Module: Event Information | GO to Pinpoint Test AS |
| RHVAC | U3000:41 | Control Module: General Checksum Failure | GO to Pinpoint Test AU |
| RHVAC | U3000:42 | Control Module: General Memory Failure | GO to Pinpoint Test AU |
| RHVAC | U3003:16 | Battery Voltage: Circuit Voltage Below Threshold | GO to Pinpoint Test AP |
| RHVAC | U3003:17 | Battery Voltage: Circuit Voltage Above Threshold | GO to Pinpoint Test AQ |
| SOBDMC | P01EB:96 | Engine Coolant Heater 'A' Control Circuit Performance: Component Internal Failure | GO to Pinpoint Test AM |
| SOBDMC | P0531:00 | A/C Refrigerant Pressure Sensor 'A' Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test A |
| SOBDMC | P0534:00 | A/C Refrigerant System 'A' Charge Loss: No Sub Type Information | GO to Pinpoint Test A |
| SOBDMC | P0D6D:00 | A/C Compressor 'A' Motor Voltage 'A' Low: No Sub Type Information | GO to Pinpoint Test AL |
| SOBDMC | P0D6F:00 | A/C Compressor 'A' Motor Current High: No Sub Type Information | GO to Pinpoint Test AL |
| SOBDMC | P0D71:00 | A/C Compressor Control Module Internal Temperature Sensor 'A' Performance: No Sub Type Information | GO to Pinpoint Test AL |
| SOBDMC | P2611:00 | A/C Refrigerant Distribution Valve 'A' Control Circuit/Open: No Sub Type Information | GO to Pinpoint Test AV |
| SOBDMC | P2612:00 | A/C Refrigerant Distribution Valve 'A' Control Circuit Low: No Sub Type Information | GO to Pinpoint Test AV |
| SOBDMC | P2613:00 | A/C Refrigerant Distribution Valve 'A' Control Circuit High: No Sub Type Information | GO to Pinpoint Test AV |
| SOBDMC | P26FD:00 | A/C Compressor 'A' Internal Control Module Performance: No Sub Type Information | GO to Pinpoint Test AL |
| SOBDMC | P2D41:00 | A/C Compressor 'A' Motor Voltage 'B' Performance: No Sub Type Information | GO to Pinpoint Test AL |
| SOBDMC | P2D42:00 | A/C Compressor 'A' Motor Voltage 'B' Low: No Sub Type Information | GO to Pinpoint Test AL |
| SOBDMC | P2D44:00 | A/C Compressor 'A' Motor Performance: No Sub Type Information | GO to Pinpoint Test AL |
| SOBDMC | P2DA4:00 | Coolant Heater 'A' Internal Control Module Performance: No Sub Type Information | GO to Pinpoint Test AM |
| SOBDMC | P2DA5:00 | Coolant Heater 'A' Supply Voltage Circuit: No Sub Type Information | GO to Pinpoint Test AM |
| SOBDMC | P2DA6:00 | Coolant Heater 'A' Over Temperature: No Sub Type Information | GO to Pinpoint Test AM |
| SOBDMC | P2DA7:00 | Coolant Heater 'A' Control Module System Voltage: No Sub Type Information | GO to Pinpoint Test AM |
| SOBDMC | P2E62:00 | Engine Coolant Bypass Valve 'E' Control Circuit/Open: No Sub Type Information | GO to Pinpoint Test AW |
| SOBDMC | P2E63:00 | Engine Coolant Bypass Valve 'E' Control Circuit Low: No Sub Type Information | GO to Pinpoint Test AW |
| SOBDMC | P2E64:00 | Engine Coolant Bypass Valve 'E' Control Circuit High: No Sub Type Information | GO to Pinpoint Test AW |
| SOBDMC | U069E:81 | Lost Communication with Coolant Heater 'B': Invalid Serial Data Received | GO to Pinpoint Test AM |
| SOBDMC | U069E:87 | Lost Communication with Coolant Heater 'B': Missing Message | GO to Pinpoint Test AM |