October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Choke Switch
- Disconnect coupler from choke switch. Check continuity between numbered terminals in coupler, using an ohmmeter.
- Continuity should exist between terminals No. 3 and No. 7 when choke knob is pulled out about 0.4" (10 mm). Continuity should exist between terminals No. 6 and No. 8 when choke knob is at any position. See Figure for terminal locations.