Check VBAT For Open To Coil

Turn key off and disconnect harness at coil pack. Turn key on. Measure voltage between coil pack harness terminal No. 4 and ground. If more than 10.5 volts are present, go to next step. If there is less than 10.5 volts, repair open circuit. Remove all test equipment and reconnect all components. Clear Continuous Memory and check for fault codes.