One Function Inoperative
- Hold control switch in specified position. See VOLTAGE TEST table. Measure voltage at specified wire terminal of appropriate motor connector. If battery voltage is present at both terminals for motor being tested, replace motor.
- If battery voltage is not present, check continuity of wiring between control switch and motor. If there is no continuity, repair wiring. If there is continuity, replace control switch.
VOLTAGE TEST
| Switch Position | Wire Terminal | |
|---|---|---|
| Slide | ||
| Forward | Green | |
| Backward | Green/White | |
| Front Lift | ||
| Up | Red | |
| Down | Red/White | |
| Rear Lift | ||
| Up | Yellow/Red | |
| Down | Yellow | |