Continuity Test
- Disconnect hydraulic unit connector. Using a DVOM, measure continuity between following wires: Yellow wire and Yellow/Red wire; Green/White wire and Yellow/Red wire; Green/Red wire and Yellow/Red wire. See Figure
. Continuity should be present in each measurement.
- If continuity is not present, replace hydraulic unit. If continuity is present, check wiring harness between ABS control unit and hydraulic unit. Repair or replace if necessary.