Main Switch

Disconnect main switch connector. Check for continuity between specified terminals of main switch with main switch button held in specified position. See MAIN SWITCH CONTINUITY TEST  . SeeFig 1 . If continuity is not as specified, replace main switch.

MAIN SWITCH CONTINUITY TEST

Switch Position (1) Terminals
Driver
UP F & N; H & L
DOWN F & L; H & N
Auto Down F & L; H & N
Off (Neutral) F, L & N
Passenger
UP B & F; D & H
DOWN B & H; D & F
Off (Neutral) B, D & F
Left Rear
UP F & K; J & M
DOWN F & M; J & K
Off (Neutral) F, K & M
Right Rear
UP A & J; C & F
DOWN A & F; C & J
Off (Neutral) A, C & F
(1) Ensure power cut switch is in ON position.
Fig 1: Identifying Main Switch Terminals
G96A06257Courtesy of MAZDA MOTORS CORP.