On-Board System Readiness Test
This shows OBD-II systems operating status. If any monitor function is incomplete, NGS tester will identify which monitor function has not been completed. Misfires, Fuel System and Comprehensive Components (CCM) are continuous monitoring-type functions and will display a "CONT" message on the screen of the NGS tester. The catalyst, EGR system, evaporation system and oxygen sensor will be monitored under drive cycles. The NGS tester will display a "YES" message once those system monitor functions are completed. The OBD-II diagnostic system is initialized by performing the DTC cancellation procedure or disconnecting the negative battery cable.