DTC P1455: Fuel Tank Level Sensor, Open Or Short Circuit: Condition
DTC is set if fuel gauge sender unit operation range is minimal when fuel consumption is over 6 gallons. Possible causes are:
- Fuel gage sending unit malfunction.
- Open or short of Green/Yellow wire between fuel gauge sending unit and terminal No. 3K on Powertrain Control Module (PCM) connector. See Figure .