TRANSAXLE RANGE (TR) SWITCH INSPECTION

Note: Input signals of the TR switch can be inspected with a NGS tester.

Inspection of Operation
1. Verify that the starter operates only with the IG SW at the START position and the selector lever in P and N positions.
- If not as specified, inspect for continuity at the TR switch.
2. Verify that the back-up lights illuminate when shifted to R position with the ignition switch at the ON position.
- If not as specified, inspect for continuity at the TR switch.

Inspection of Continuity
1. Disconnect the negative battery cable.
2. Remove the fresh-air duct and air cleaner component





3. Disconnect the TR switch connector.








4. Inspect for continuity at the TR switch.
- If not as specified, replace or adjust the TR switch.
5. Connect the TR switch connector.
6. Install the air cleaner component and fresh-air duct.
7. Connect the negative battery cable.