Front HO2S heater control
- Terminal connected: 1V (+)-Negative battery terminal
- Oscilloscope setting: 5 V/DIV (Y): 50 ms/DIV (X), DC range
- Measurement condition: Idling after warm-up (no load)
Courtesy of MAZDA MOTORS CORP.