| DETECTION CONDITION |
- The PCM monitors the input voltage from the front HO2S when the following conditions are met. Under the following monitoring conditions, if the input voltage from the front HO2S does not even exceed 0.55 V
though the short term fuel trim is controlled up to 25%
for 9.6 s
, the PCM determines that sensor circuit is not activated.
MONITORING CONDITIONS
- HO2S, HO2S heater and TWC Repair Verification Drive Mode
- Following conditions are met
- Time from engine start is above 49.8 s
(ECT when engine start is 20 °C {68 °F}
).
- Front HO2S voltage is above 0.1 V
Diagnostic support note
- This is an intermittent monitor (HO2S).
- MIL illuminates if the PCM detects the above malfunction condition in two consecutive drive cycles or in one drive cycle while the DTC for the same malfunction has been stored in the PCM.
- PENDING CODE is available if the PCM detects the above malfunction condition during the first drive cycle.
- FREEZE FRAME DATA is available.
- DTC is stored in the PCM memory.
|