LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2006 >> B3000 Base, Automatic >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Anti-Theft Systems >> Troubleshooting (Security System And Locks System) >> Pinpoint Test 1: All Door Locks Are Inoperative From One Switch >> Normal Operation
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Normal Operation

The smart junction box (SJB) monitors circuits (P/Y), (P/LG), (O/B) and (Y/R) for a ground signal. If the door lock control switch connects circuit (P/LG) (driver door) or (O/B) (passenger door) to the ground circuit (B) the doors lock. If the door lock control switch connects circuit (P/Y) (driver door) or (Y/R) (passenger door) to the ground circuit (B) the doors unlock.