Possible Causes
- ISO 9141 communication network circuit (LB/W) open
- RCM 0810-101
- RCM
CAUTION:
- Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
RESTRAINT CONTROL MODULE (RCM) DOES NOT RESPOND TO DIAGNOSTIC TOOL PINPOINT TEST REFERENCE
| PIN POINT TEST 2 | RESTRAINT CONTROL MODULE (RCM) DOES NOT RESPOND TO THE DIAGNOSTIC TOOL | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK THE RCM 0810-101 FOR DAMAGE
|
Yes | Go to next step. |
| No | Repair the RCM 0810-101. CONNECT the RCM 0810-101. Activate the air bag system. See SUPPLEMENTAL RESTRAINT SYSTEM (SRS) DEACTIVATION AND REACTIVATION . Carry out the WDS or equivalent tester data link test. | ||
| 20 | CHECK THE ISO 9141 CIRCUIT BETWEEN THE DLC AND THE RCM FOR AN OPEN
|
Yes | Go to next step. |
| No | Repair circuit (LB/W) for an open. Connect the RCM 0810-101. ACTIVATE the air bag system. See SUPPLEMENTAL RESTRAINT SYSTEM (SRS) DEACTIVATION AND REACTIVATION . Carry out the WDS or equivalent tester data link test. | ||
| 3 | CHECK FOR CORRECT RCM OPERATION
|
Yes | Install a new RCM. See RESTRAINTS CONTROL MODULE (RCM) . Carry out the WDS or equivalent tester data link test. |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. Clear the diagnostic trouble codes (DTCs). Repeat the self-test. Carry out the WDS or equivalent tester data link test. | ||